CVE-2025-3618
A denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.78%
- Percentil entre todas las CVEs puntuadas: 78
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation75 % - Impacto principal
T1499.004Application or System Exploitationimpact80 %
AV:L/PR:L sin interacción indica escalada local; CWE-119 (buffer overflow) en procesamiento de mensajes causa DoS por fallo de asignación de memoria.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-3618",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-3618",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-04-15T17:40:46.050596Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.5,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.5,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation",
"product": "ThinManager",
"versions": [
{
"status": "affected",
"version": "v14.0.1 and earlier"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-04-15T18:15:53.767",
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1727.html",
"tags": [
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de denegación de servicio en Rockwell Automation ThinManager. El software no verifica adecuadamente el resultado de la asignación de memoria al procesar mensajes de tipo 18. Si se explota, un atacante podría provocar una denegación de servicio en el software objetivo."
}
],
"lastModified": "2026-06-17T09:20:18.783",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "5B3C2FCE-D93F-4EB6-A376-7F45D990CEC7",
"versionEndExcluding": "11.2.11"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "15BB8CC2-E068-4DE0-AFED-18A347780A6D",
"versionEndExcluding": "12.0.9",
"versionStartIncluding": "12.0.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "6A02BD87-497D-41A4-A43E-A2C57A4EB1B7",
"versionEndExcluding": "12.1.10",
"versionStartIncluding": "12.1.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "854BB218-0C31-4B15-B985-667CFB4327C6",
"versionEndExcluding": "13.0.7",
"versionStartIncluding": "13.0.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "16640933-7F09-4191-99CB-5B98414C12E7",
"versionEndExcluding": "13.1.5",
"versionStartIncluding": "13.1.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "55443917-D3EF-4BF2-A835-5315590E3190",
"versionEndExcluding": "13.2.4",
"versionStartIncluding": "13.2.0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DFAAF709-3C91-408C-A368-EB2EA0E6B5FA",
"versionEndExcluding": "14.0.2",
"versionStartIncluding": "14.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}