Estado: AnalizadaMedia (5.1)—

D-Link Nuclias Connect firmware versions <= 1.3.1.4 contain a stored cross-site scripting (XSS) vulnerability due to improper sanitization of the 'Network' field when editing the configuration, creating a profile, and adding a network. An authenticated attacker can inject arbitrary JavaScript to be executed in the context of other users viewing the profile entry. NOTE: D-Link states that a fix is under development.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-34253",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-34253",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-10-17T14:28:34.087394Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 5.4,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "LOW"
        },
        "impactScore": 2.7,
        "exploitabilityScore": 2.3
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 5.1,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "PASSIVE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "LOW",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "LOW",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "D-Link",
          "product": "Nuclias Connect",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "1.3.1.4",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-10-16T19:15:32.620",
  "references": [
    {
      "url": "https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10472",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.dlink.com/en/for-business/nuclias/nuclias-connect",
      "tags": [
        "Product"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.vulncheck.com/advisories/dlink-nuclias-connect-stored-xss",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link Nuclias Connect firmware versions <= 1.3.1.4 contain a stored cross-site scripting (XSS) vulnerability due to improper sanitization of the 'Network' field when editing the configuration, creating a profile, and adding a network. An authenticated attacker can inject arbitrary JavaScript to be executed in the context of other users viewing the profile entry. NOTE: D-Link states that a fix is under development."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de D-Link Nuclias Connect menor o igual a 1.3.1.4 contienen una vulnerabilidad de cross-site scripting (XSS) almacenado debido a la sanitización inadecuada del campo 'Network' al editar la configuración, crear un perfil y añadir una red. Un atacante autenticado puede inyectar JavaScript arbitrario para ser ejecutado en el contexto de otros usuarios que visualizan la entrada del perfil. NOTA: D-Link afirma que una solución está en desarrollo."
    }
  ],
  "lastModified": "2026-10-05T14:10:00.267",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:dlink:nuclias_connect:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1DDE121F-E175-450D-A078-A7BF6F643415",
              "versionEndIncluding": "1.3.1.4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com"
}