CVE-2025-2981
Estado: AplazadaMedia (5.1)—
A vulnerability, which was classified as problematic, has been found in Legrand SMS PowerView 1.x. This issue affects some unknown processing. The manipulation of the argument redirect leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.24%
- Percentil entre todas las CVEs puntuadas: 14
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-79, CWE-94
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-2981",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-2981",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-31T12:40:10.543644Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 4,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 3.5,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 1.4,
"exploitabilityScore": 2.1
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.1,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Legrand",
"product": "SMS PowerView",
"versions": [
{
"status": "affected",
"version": "1.x"
}
]
}
]
}
],
"published": "2025-03-31T07:15:18.937",
"references": [
{
"url": "https://vuldb.com/?ctiid.302033",
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.302033",
"source": "cna@vuldb.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
},
{
"lang": "en",
"value": "CWE-94"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, has been found in Legrand SMS PowerView 1.x. This issue affects some unknown processing. The manipulation of the argument redirect leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad clasificada como problemática en Legrand SMS PowerView 1.x. Este problema afecta a algunos procesos desconocidos. La manipulación de la redirección de argumentos provoca Cross Site Scripting. El ataque podría iniciarse remotamente. Se ha hecho público el exploit y puede que sea utilizado. Se contactó al proveedor con antelación para informarle sobre esta divulgación, pero no respondió."
}
],
"lastModified": "2026-06-17T09:07:57.207",
"sourceIdentifier": "cna@vuldb.com"
}