« Volver al listado

CVE-2025-2884

Estado: AplazadaMedia (6.6)—

TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-2884",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-2884",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-06-13T01:41:10.489446Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.6,
          "attackVector": "LOCAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 1.3
      }
    ]
  },
  "affected": [
    {
      "source": "cret@cert.org",
      "affectedData": [
        {
          "vendor": "Trusted Computing Group",
          "product": "TPM2.0",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "1.83",
              "versionType": "custom"
            }
          ]
        }
      ]
    },
    {
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMATIC CN 4100",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Field PG M5",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Field PG M6",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V26.01.14",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-32A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V29.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-39A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V29.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-56A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V32.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-59A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V32.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC MD-57A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V30.01.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC PX-32A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V29.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC PX-39A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V29.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC PX-39A PRO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V29.01.09",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC RW-528A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V34.01.02",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC RW-548A",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V34.01.02",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC227E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC277E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC427E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.20",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC477E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.20",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC477E PRO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.20",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC627E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC647E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC677E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC847E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC ITP1000",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "*",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIPLUS IPC427E",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V21.01.20",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-06-10T18:15:30.617",
  "references": [
    {
      "url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1",
      "source": "cret@cert.org"
    },
    {
      "url": "https://trustedcomputinggroup.org/about/security/",
      "source": "cret@cert.org"
    },
    {
      "url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf",
      "source": "cret@cert.org"
    },
    {
      "url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf",
      "source": "cret@cert.org"
    },
    {
      "url": "https://www.cve.org/CVERecord?id=CVE-2025-49133",
      "source": "cret@cert.org"
    },
    {
      "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.kb.cert.org/vuls/id/282450",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html",
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
    },
    {
      "lang": "es",
      "value": "La función auxiliar CryptHmacSign de la implementación de referencia TCG TPM2.0 es vulnerable a lecturas fuera de los límites debido a la falta de validación del esquema de firma con el algoritmo de la clave de firma. Consulte la errata 1.83 del estándar TCG TPM2.0."
    }
  ],
  "lastModified": "2026-08-11T13:17:28.053",
  "sourceIdentifier": "cret@cert.org"
}