« Volver al listado

CVE-2025-27702

Estado: AnalizadaMedia (6.9)—

CVE-2025-27702 is a vulnerability in the management console of Absolute Secure Access prior to version 13.54. Attackers with administrative access to the console and who have been assigned a certain set of permissions can bypass those permissions to improperly modify settings. The attack complexity is low, there are no preexisting attack requirements; the privileges required are high, and there is no user interaction required. There is no impact to system confidentiality or availability, impact to system integrity is high.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-27702",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-27702",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-05-28T23:49:57.998713Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.9,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.2
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "SecurityResponse@netmotionsoftware.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6.9,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "SecurityResponse@netmotionsoftware.com",
      "affectedData": [
        {
          "vendor": "Absolute Security",
          "product": "Secure Access",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "13.54",
              "versionType": "Server Version"
            }
          ],
          "packageName": "Management Console",
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-05-28T21:15:21.307",
  "references": [
    {
      "url": "https://www.absolute.com/platform/vulnerability-archive/cve-2025-27702",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "SecurityResponse@netmotionsoftware.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "CVE-2025-27702 is a vulnerability in the management console of Absolute \nSecure Access prior to version 13.54. Attackers with administrative \naccess to the console and who have been assigned a certain set of \npermissions can bypass those permissions to improperly modify settings. \nThe attack complexity is low, there are no preexisting attack \nrequirements; the privileges required are high, and there is no user \ninteraction required. There is no impact to system confidentiality or \navailability, impact to system integrity is high."
    },
    {
      "lang": "es",
      "value": "CVE-2025-27702 es una vulnerabilidad en la consola de administración de Absolute Secure Access anterior a la versión 13.54. Los atacantes con acceso administrativo a la consola y con ciertos permisos asignados pueden eludirlos para modificar la configuración de forma indebida. La complejidad del ataque es baja, no existen requisitos previos; se requieren privilegios elevados y no se requiere interacción del usuario. No se ve afectada la confidencialidad ni la disponibilidad del sistema, pero sí la integridad del mismo."
    }
  ],
  "lastModified": "2026-06-17T09:04:05.183",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:absolute:secure_access:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "30A5DDF4-1B4A-4867-8F0B-9ECD4F5A538F",
              "versionEndExcluding": "13.54"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "SecurityResponse@netmotionsoftware.com"
}