A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-26409",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-26409",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-02-11T14:38:08.176508Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.8,
          "attackVector": "PHYSICAL",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 0.9
      }
    ]
  },
  "affected": [
    {
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
      "affectedData": [
        {
          "vendor": "Wattsense",
          "product": "Wattsense Bridge",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "6.4.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2025-02-11T10:15:09.743",
  "references": [
    {
      "url": "https://r.sec-consult.com/wattsense",
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
    },
    {
      "url": "https://support.wattsense.com/hc/en-150/articles/13366066529437-Release-Notes",
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
    },
    {
      "url": "http://seclists.org/fulldisclosure/2025/Feb/9",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1191"
        },
        {
          "lang": "en",
          "value": "CWE-1299"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-1299"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1."
    },
    {
      "lang": "es",
      "value": "Se puede acceder a una interfaz serial con acceso físico a la PCB de los dispositivos Wattsense Bridge. Después de conectarse a la interfaz, es posible acceder al gestor de arranque, así como a un mensaje de inicio de sesión de Linux. El acceso al gestor de arranque se puede utilizar para obtener un shell raíz en el dispositivo. Este problema se ha solucionado en las versiones de firmware recientes BSP >= 6.4.1."
    }
  ],
  "lastModified": "2026-06-17T09:01:43.317",
  "sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf"
}