CVE-2025-25635
TOTOlink A3002R V1.1.1-B20200824.0128 contains a buffer overflow vulnerability. The vulnerability arises from the improper input validation of the pppoe_dns1 parameter in the formIpv6Setup interface of /bin/boa.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.42%
- Percentil entre todas las CVEs puntuadas: 34
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1059Command and Scripting Interpreterexecution80 % - Impacto secundario
T1068Exploitation for Privilege Escalationprivilege escalation70 %
Buffer overflow en servicio remoto (boa) accesible en red adyacente (AV:A, PR:L). Permite ejecución de código (CWE-120) y potencial escalada de privilegios en dispositivo embebido.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-120
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-25635",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-25635",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-03-05T15:45:05.520026Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.1
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2025-02-28T19:15:37.223",
"references": [
{
"url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/ToTolink/TOTOLINK-A3002R-formIpv6Setup-pppoe_dns1.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TOTOlink A3002R V1.1.1-B20200824.0128 contains a buffer overflow vulnerability. The vulnerability arises from the improper input validation of the pppoe_dns1 parameter in the formIpv6Setup interface of /bin/boa."
},
{
"lang": "es",
"value": "TOTOlink A3002R V1.1.1-B20200824.0128 contiene una vulnerabilidad de desbordamiento de búfer. La vulnerabilidad surge de la validación de entrada incorrecta del parámetro pppoe_dns1 en la interfaz formIpv6Setup de /bin/boa."
}
],
"lastModified": "2026-06-17T09:00:59.020",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:totolink:a3002r_firmware:1.1.1-b20200824.0128:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "1380E8DE-E6D6-44B4-B6E5-407B63AC6656"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:totolink:a3002r:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "2CBBBC48-8918-4D59-8059-285404AE7716"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}