CVE-2025-24917
In Tenable Network Monitor versions prior to 6.5.1 on a Windows host, it was found that a non-administrative user could stage files in a local directory to run arbitrary code with SYSTEM privileges, potentially leading to local privilege escalation.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.16%
- Percentil entre todas las CVEs puntuadas: 5
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1068Exploitation for Privilege Escalationprivilege escalation95 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 % - Impacto secundario
T1548Abuse Elevation Control Mechanismprivilege escalation85 %
AV:L + PR:L sin UI:N confirma escalada de privilegios local (T1068). Ejecución de código arbitrario con SYSTEM (T1059) y elevación a privilegios administrativos (T1548) como resultados.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (1)
CWE
- CWE-284
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-24917",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-24917",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-05-28T03:56:00.741169Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "vulnreport@tenable.com",
"affectedData": [
{
"vendor": "Tenable",
"product": "Network Monitor",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "6.5.1",
"versionType": "semver"
}
],
"platforms": [
"Windows"
],
"defaultStatus": "affected"
}
]
}
],
"published": "2025-05-23T16:15:25.163",
"references": [
{
"url": "https://www.tenable.com/security/tns-2025-10",
"tags": [
"Vendor Advisory"
],
"source": "vulnreport@tenable.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "vulnreport@tenable.com",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Tenable Network Monitor versions prior to 6.5.1 on a Windows host, it was found that a non-administrative user could stage files in a local directory to run arbitrary code with SYSTEM privileges, potentially leading to local privilege escalation."
},
{
"lang": "es",
"value": "En versiones de Tenable Network Monitor anteriores a 6.5.1 en un host Windows, se descubrió que un usuario no administrativo podía almacenar archivos en un directorio local para ejecutar código arbitrario con privilegios de SYSTEM, lo que potencialmente podía provocar una escalada de privilegios locales."
}
],
"lastModified": "2026-06-17T08:59:50.450",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:tenable:nessus_network_monitor:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "AA44DDD5-1D56-4A42-99E6-EE5076D84896",
"versionEndExcluding": "6.5.1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "vulnreport@tenable.com"
}