CVE-2025-1977
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.35%
- Percentil entre todas las CVEs puntuadas: 26
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement75 % - Impacto principal
T1068Exploitation for Privilege Escalationprivilege escalation80 % - Impacto secundario
T1565.001Stored Data Manipulationimpact70 %
Acceso remoto en red (AV:N) con privilegios autenticados (PR:L) sin interacción. CWE-250 (ejecución con privilegios innecesarios) permite al usuario read-only cambiar configuración no autorizada, escalando efectivamente. Integridad y disponibilidad comprometidas.
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (2)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-250
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-1977",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-1977",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2025-12-31T16:08:52.042249Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "psirt@moxa.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "psirt@moxa.com",
"affectedData": [
{
"vendor": "Moxa",
"product": "NPort 6100-G2/6200-G2 Series",
"versions": [
{
"status": "affected",
"version": "1.0.0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.1.0",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-12-31T08:15:45.310",
"references": [
{
"url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-251731-cve-2025-1977-cve-2025-2026-multiple-vulnerabilities-in-nport-6100-g2-6200-g2-series",
"source": "psirt@moxa.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@moxa.com",
"description": [
{
"lang": "en",
"value": "CWE-250"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified."
},
{
"lang": "es",
"value": "La serie NPort 6100-G2/6200-G2 está afectada por una vulnerabilidad de ejecución con privilegios innecesarios (CVE-2025-1977) que permite a un usuario autenticado con acceso de solo lectura realizar cambios de configuración no autorizados a través de la herramienta MCC (Moxa CLI Configuration). El problema puede ser explotado remotamente a través de la red con baja complejidad de ataque y sin interacción del usuario, pero requiere que estén presentes condiciones o configuraciones específicas del sistema. La explotación exitosa puede resultar en cambios en la configuración del dispositivo que no estaban destinados a ser permitidos para el rol de usuario afectado, lo que podría llevar a un alto impacto en la confidencialidad, integridad y disponibilidad del dispositivo. No se ha identificado ningún impacto en otros sistemas."
}
],
"lastModified": "2026-06-17T08:40:28.180",
"sourceIdentifier": "psirt@moxa.com"
}