CVE-2025-1418
Estado: AplazadaMedia (5.1)—
A low-privileged user can access information about profiles created in Proget MDM (Mobile Device Management), which contain details about allowed/prohibited functions. The profiles do not reveal any sensitive information (including their usage in connected devices).
This issue has been fixed in 2.17.5 version of Konsola Proget (server part of the MDM suite).
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.18%
- Percentil entre todas las CVEs puntuadas: 7
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-863
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2025-1418",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-1418",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-21T13:25:58.736936Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.1,
"Automatable": "NOT_DEFINED",
"attackVector": "ADJACENT",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cvd@cert.pl",
"affectedData": [
{
"vendor": "Proget",
"product": "Proget",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2.17.5",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-05-21T13:16:01.927",
"references": [
{
"url": "https://cert.pl/en/posts/2025/05/CVE-2025-1415",
"source": "cvd@cert.pl"
},
{
"url": "https://proget.pl/en/mobile-device-management/",
"source": "cvd@cert.pl"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"description": [
{
"lang": "en",
"value": "CWE-863"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A low-privileged user can access information about profiles created in Proget MDM (Mobile Device Management), which contain details about allowed/prohibited functions. The profiles do not reveal any sensitive information (including their usage in connected devices). \n\n\nThis issue has been fixed in 2.17.5 version of Konsola Proget (server part of the MDM suite)."
},
{
"lang": "es",
"value": "Un usuario con pocos privilegios puede acceder a la información sobre los perfiles creados en Proget MDM (Administración de Dispositivos Móviles), que contiene detalles sobre las funciones permitidas/prohibidas. Los perfiles no revelan información confidencial (incluido su uso en los dispositivos conectados). Este problema se ha solucionado en la versión 2.17.5 de Konsola Proget (la parte del servidor de la suite MDM)."
}
],
"lastModified": "2026-06-17T08:39:06.063",
"sourceIdentifier": "cvd@cert.pl"
}