« Volver al listado

CVE-2025-10258

Estado: ModificadaMedia (6.3)—

Infinera DNA is vulnerable to a time-based SQL injection vulnerability due to insufficient input validation, which may result in leaking of sensitive information.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2025-10258",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-10258",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2026-02-05T14:33:46.630378Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.3,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "LOW",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 2.1
      }
    ]
  },
  "affected": [
    {
      "source": "b48c3b8f-639e-4c16-8725-497bc411dad0",
      "affectedData": [
        {
          "vendor": "Nokia",
          "product": "Infinera DNA",
          "versions": [
            {
              "status": "affected",
              "version": "Earlier than R24.2"
            },
            {
              "status": "unaffected",
              "version": "R24.2 and later"
            }
          ]
        }
      ]
    }
  ],
  "published": "2026-02-05T08:16:07.500",
  "references": [
    {
      "url": "https://www.nokia.com/we-are-nokia/security/product-security-advisory/cve-2025-10258/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "b48c3b8f-639e-4c16-8725-497bc411dad0"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Infinera DNA is vulnerable to a time-based SQL injection vulnerability due to insufficient input validation, which may result in leaking of sensitive information."
    },
    {
      "lang": "es",
      "value": "Infinera DNA es vulnerable a una vulnerabilidad de inyección SQL basada en tiempo debido a una validación de entrada insuficiente, lo que puede resultar en la fuga de información sensible."
    }
  ],
  "lastModified": "2026-06-17T08:28:00.620",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:nokia:infinera_dna:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "517B4079-06FC-4304-AF33-95B19A3264A9",
              "versionEndExcluding": "r24.2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "b48c3b8f-639e-4c16-8725-497bc411dad0"
}