« Volver al listado

CVE-2024-8957

Estado: AnalizadaAlta (7.2)⚠ Explotación activa

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

CISA KEV — explotada activamente

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

OS command injection en servicio NTP remoto (AV:N, CWE-78) permite ejecución de comandos arbitrarios. PR:H sugiere requiere privilegios de red/acceso previo o cadena de explotación (CVE-2024-8956 citado).

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-8957",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-8957",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "active"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-09-08T18:25:10.384044Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "disclosure@vulncheck.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ]
  },
  "affected": [
    {
      "source": "disclosure@vulncheck.com",
      "affectedData": [
        {
          "vendor": "PTZOptics",
          "product": "PT30X-SDI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "6.3.40",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "PTZOptics",
          "product": "PT30X-NDI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "6.3.40",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "ptzoptics",
          "product": "pt30x-sdi_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "6.3.40",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:ptzoptics:pt30x-ndi_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "ptzoptics",
          "product": "pt30x-ndi_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "6.3.40",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-09-17T21:15:13.423",
  "references": [
    {
      "url": "https://ptzoptics.com/firmware-changelog/",
      "tags": [
        "Release Notes"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://vulncheck.com/advisories/ptzoptics-command-injection",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "disclosure@vulncheck.com"
    },
    {
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8957",
      "tags": [
        "US Government Resource"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    },
    {
      "url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    },
    {
      "url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "disclosure@vulncheck.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices."
    },
    {
      "lang": "es",
      "value": "PTZOptics PT30X-SDI/NDI-xx anterior al firmware 6.3.40 es vulnerable a un problema de inyección de comandos del sistema operativo. La cámara no valida suficientemente el valor de configuración ntp_addr, lo que puede provocar la ejecución de comandos arbitrarios cuando se inicia ntp_client. Cuando se combina con CVE-2024-8956, un atacante remoto y no autenticado puede ejecutar comandos arbitrarios del sistema operativo en los dispositivos afectados."
    }
  ],
  "lastModified": "2026-06-17T08:23:37.947",
  "cisaActionDue": "2024-11-25",
  "cisaExploitAdd": "2024-11-04",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "604C6EEF-4273-4366-AFF2-86C3183F545D",
              "versionEndExcluding": "6.3.40"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "7462D89D-2105-417F-AB0E-D23C288156C8"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B410E242-DFEE-449D-9687-6F4D0BEB8F63",
              "versionEndExcluding": "6.3.40"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C8F75E95-D59D-45D4-B798-D0493642F53E"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "disclosure@vulncheck.com",
  "cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.",
  "cisaVulnerabilityName": "PTZOptics PT30X-SDI/NDI Cameras OS Command Injection Vulnerability"
}