Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream. The credentials are being sent when a user decides to change his password in router's portal.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 6
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 10
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-319
Referencias
- https://cert.pl/en/posts/2024/07/CVE-2024-5631/
- https://cert.pl/posts/2024/07/CVE-2024-5631
- https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01
- https://cert.pl/en/posts/2024/07/CVE-2024-5631/
- https://cert.pl/posts/2024/07/CVE-2024-5631
- https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-5631",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "cvd@cert.pl"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-5631",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-07-09T15:12:14.314814Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 6,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "cvd@cert.pl",
"affectedData": [
{
"vendor": "Longse Technology",
"product": "NVR3608PGE2W",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "*"
}
],
"defaultStatus": "affected"
},
{
"vendor": "Zamel",
"product": "ZMB-01",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "*"
}
],
"defaultStatus": "affected"
}
]
}
],
"published": "2024-07-09T11:15:15.740",
"references": [
{
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/",
"source": "cvd@cert.pl"
},
{
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631",
"source": "cvd@cert.pl"
},
{
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01",
"source": "cvd@cert.pl"
},
{
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "cvd@cert.pl",
"description": [
{
"lang": "en",
"value": "CWE-319"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream. \nThe credentials are being sent when a user decides to change his password in router's portal."
},
{
"lang": "es",
"value": " Longse NVR (Network Video Recorder) modelo NVR3608PGE2W, así como los productos basados en este dispositivo, transmiten el nombre de usuario y la contraseña a un servicio de control remoto sin utilizar ningún cifrado. Esto permite a un atacante en ruta espiar las credenciales y posteriormente obtener acceso a la transmisión de video. Las credenciales se envían cuando un usuario decide cambiar su contraseña en el portal del enrutador."
}
],
"lastModified": "2026-06-17T08:16:19.483",
"sourceIdentifier": "cvd@cert.pl"
}