« Volver al listado

CVE-2024-50372

Estado: AnalizadaCrítica (9.8)—

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector CVSS AV:N/AC:L/PR:N/UI:N indica acceso remoto sin autenticación ni interacción. CWE-78 (OS Command Injection) en servicio 'edgserver' sin protección permite inyección de comandos ejecutados como root.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (3)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-50372",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-50372",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-11-26T14:11:11.452183Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.8,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "prodsec@nozominetworks.com",
      "affectedData": [
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-2G",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.6.3"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-2GD",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.6.3"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Advantech",
          "product": "EKI-6333AC-1GPO",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "semver",
              "lessThanOrEqual": "<= 1.2.1"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-2g_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.6.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-2gd_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.6.3"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
          ],
          "vendor": "advantech",
          "product": "eki-6333ac-1gpo_firmware",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.2.1"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-11-26T11:22:06.457",
  "references": [
    {
      "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50372",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "prodsec@nozominetworks.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "prodsec@nozominetworks.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default \"edgserver\" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the \"backup_config_to_utility\" operation."
    },
    {
      "lang": "es",
      "value": "Se descubrió una vulnerabilidad CWE-78 \"Neutralización incorrecta de elementos especiales utilizados en un comando del SO ('Inyección de comando del SO')\" que afecta a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (&lt;= 1.6.3), EKI-6333AC-2GD (&lt;= v1.6.3) y EKI-6333AC-1GPO (&lt;= v1.2.1). La vulnerabilidad puede ser explotada por usuarios remotos no autenticados capaces de interactuar con el servicio \"edgserver\" predeterminado habilitado en el punto de acceso y se ejecutan comandos maliciosos con privilegios de superusuario. No hay autenticación habilitada en el servicio y la fuente de la vulnerabilidad reside en el código de procesamiento asociado a la operación \"backup_config_to_utility\"."
    }
  ],
  "lastModified": "2026-06-17T08:04:19.750",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B5E027C8-2521-45FC-BABB-4A6E3341F883",
              "versionEndExcluding": "1.6.5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B3B63DF4-0184-4108-B48B-D31179104701"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "447F8AEB-2C7C-411A-893C-11C2F7588C82",
              "versionEndExcluding": "1.6.5"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "02F70DBA-2D4C-4407-885D-71887A1A7979"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "828B9D05-0064-4690-A624-D3BF659BD316",
              "versionEndExcluding": "1.2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D2A73A2B-9FD5-4971-8FFF-1BA14BCCB37B"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "prodsec@nozominetworks.com"
}