CVE-2024-50355
Estado: AnalizadaMedia (4.8)—
LibreNMS is an open-source, PHP/MySQL/SNMP-based network monitoring system. User with Admin role can edit the Display Name of a device, the application did not properly sanitize the user input in the device Display Name, if java script code is inside the name of the device Display Name, its can be trigger from different sources. This vulnerability is fixed in 24.10.0.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 4.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.32%
- Percentil entre todas las CVEs puntuadas: 23
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-79
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-50355",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-50355",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-11-15T16:05:39.086737Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "security-advisories@github.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 4.8,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 1.7
}
]
},
"affected": [
{
"source": "security-advisories@github.com",
"affectedData": [
{
"vendor": "librenms",
"product": "librenms",
"versions": [
{
"status": "affected",
"version": "< 24.10.0"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:librenms:librenms:*:*:*:*:*:*:*:*"
],
"vendor": "librenms",
"product": "librenms",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "24.10.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-15T16:15:36.160",
"references": [
{
"url": "https://github.com/librenms/librenms/commit/bb4731419b592867bf974dde525e536606a52976",
"tags": [
"Patch"
],
"source": "security-advisories@github.com"
},
{
"url": "https://github.com/librenms/librenms/security/advisories/GHSA-4m5r-w2rq-q54q",
"tags": [
"Exploit",
"Vendor Advisory"
],
"source": "security-advisories@github.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "security-advisories@github.com",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "LibreNMS is an open-source, PHP/MySQL/SNMP-based network monitoring system. User with Admin role can edit the Display Name of a device, the application did not properly sanitize the user input in the device Display Name, if java script code is inside the name of the device Display Name, its can be trigger from different sources. This vulnerability is fixed in 24.10.0."
},
{
"lang": "es",
"value": "LibreNMS es un sistema de monitoreo de red de código abierto basado en PHP/MySQL/SNMP. El usuario con rol de administrador puede editar el nombre para mostrar de un dispositivo, la aplicación no saneó correctamente la entrada del usuario en el nombre para mostrar del dispositivo, si el código de script de Java está dentro del nombre para mostrar del dispositivo, puede ser activado desde diferentes fuentes. Esta vulnerabilidad se corrigió en 24.10.0."
}
],
"lastModified": "2026-06-17T08:04:17.730",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:librenms:librenms:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B4BD88D2-5DA7-450B-AEFA-33BCA61685A7",
"versionEndExcluding": "24.10.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "security-advisories@github.com"
}