« Volver al listado

CVE-2024-5000

Estado: AplazadaAlta (7.5)—

An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-5000",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-5000",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-06-06T14:26:44.507505Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "info@cert.vde.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.5,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "info@cert.vde.com",
      "affectedData": [
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for BeagleBone SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for IOT2000 SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for Linux ARM SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for Linux SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for PFC100 SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for PFC200 SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for PLCnext SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for Raspberry Pi SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control RTE (SL)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Runtime Toolkit",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS Control Win (SL)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "CODESYS",
          "product": "CODESYS HMI (SL)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_empc-a\\/imx6_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_beaglebone_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_iot2000_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_linux_arm_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_linux_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_pfc200_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_plcnext_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_raspberry_pi_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_for_wago_touch_panels_600_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "4.12.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_rte_\\(for_beckhoff_cx\\)_sl",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_rte_\\(sl\\)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "control_win_\\(sl\\)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "runtime_toolkit",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
          ],
          "vendor": "codesys",
          "product": "hmi_\\(sl\\)",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.5.20.10",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-06-04T09:15:09.830",
  "references": [
    {
      "url": "https://cert.vde.com/en/advisories/VDE-2024-026",
      "source": "info@cert.vde.com"
    },
    {
      "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18355&token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1&download=",
      "source": "info@cert.vde.com"
    },
    {
      "url": "https://cert.vde.com/en/advisories/VDE-2024-026",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=18355&token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1&download=",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "info@cert.vde.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-131"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
    },
    {
      "lang": "es",
      "value": "Un atacante remoto no autenticado puede utilizar un cliente OPC UA malicioso para enviar una solicitud manipulada a los productos CODESYS afectados, lo que puede provocar un DoS debido a un cálculo incorrecto del tamaño del búfer."
    }
  ],
  "lastModified": "2026-06-17T08:14:52.690",
  "sourceIdentifier": "info@cert.vde.com"
}