CVE-2024-47573
Estado: AnalizadaMedia (6.5)—
An improper validation of integrity check value vulnerability [CWE-354] in FortiNDR version 7.4.2 and below, version 7.2.1 and below, version 7.1.1 and below, version 7.0.6 and below may allow an authenticated attacker with at least Read/Write permission on system maintenance to install a corrupted firmware image.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
- Puntuación base: 6.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.21%
- Percentil entre todas las CVEs puntuadas: 11
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-354
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-47573",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-47573",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-03-14T17:53:14.212011Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@fortinet.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.5,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "psirt@fortinet.com",
"affectedData": [
{
"vendor": "Fortinet",
"product": "FortiNDR",
"versions": [
{
"status": "affected",
"version": "7.4.0",
"versionType": "semver",
"lessThanOrEqual": "7.4.2"
},
{
"status": "affected",
"version": "7.2.0",
"versionType": "semver",
"lessThanOrEqual": "7.2.1"
},
{
"status": "affected",
"version": "7.1.0",
"versionType": "semver",
"lessThanOrEqual": "7.1.1"
},
{
"status": "affected",
"version": "7.0.0",
"versionType": "semver",
"lessThanOrEqual": "7.0.6"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-03-14T15:15:43.363",
"references": [
{
"url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-461",
"tags": [
"Vendor Advisory"
],
"source": "psirt@fortinet.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@fortinet.com",
"description": [
{
"lang": "en",
"value": "CWE-354"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper validation of integrity check value vulnerability [CWE-354] in FortiNDR version 7.4.2 and below, version 7.2.1 and below, version 7.1.1 and below, version 7.0.6 and below may allow an authenticated attacker with at least Read/Write permission on system maintenance to install a corrupted firmware image."
},
{
"lang": "es",
"value": "Una vulnerabilidad de validación incorrecta del valor de verificación de integridad [CWE-354] en FortiNDR versión 7.4.2 y anteriores, versión 7.2.1 y anteriores, versión 7.1.1 y anteriores, versión 7.0.6 y anteriores puede permitir que un atacante autenticado con al menos permiso de lectura/escritura en mantenimiento del sistema instale una imagen de firmware dañada."
}
],
"lastModified": "2026-06-17T07:57:20.040",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:fortinet:fortindr:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A083B022-481F-4C9C-BB84-7B97885BF7FD",
"versionEndExcluding": "7.2.2",
"versionStartIncluding": "7.0.0"
},
{
"criteria": "cpe:2.3:a:fortinet:fortindr:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9CA704E7-0DED-4CF0-A6DE-705CD2BCC476",
"versionEndExcluding": "7.4.3",
"versionStartIncluding": "7.4.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@fortinet.com"
}