« Volver al listado

CVE-2024-47135

Estado: AnalizadaAlta (7.8)—

Stack-based buffer overflow vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.14.0 and earlier. Having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier may cause a denial-of-service (DoS) condition, arbitrary code execution, and/or information disclosure because the issues exist in parsing of KPP project files.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vector CVSS con UI:R (interacción usuario: abrir archivo .KPP preparado). Texto explícita ejecución arbitraria de código y DoS. Buffer overflow en parseo de fichero requiere acción usuario.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-47135",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-47135",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-10-03T15:31:50.339454Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "vultures@jpcert.or.jp",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "vultures@jpcert.or.jp",
      "affectedData": [
        {
          "vendor": "JTEKT ELECTRONICS CORPORATION",
          "product": "Kostac PLC Programming Software (Former name: Koyo PLC Programming Software)",
          "versions": [
            {
              "status": "affected",
              "version": "1.6.14.0 and earlier"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:jtekt:kostac_plc_programming_software:*:*:*:*:*:*:*:*"
          ],
          "vendor": "jtekt",
          "product": "kostac_plc_programming_software",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "1.6.14.0"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-10-03T03:15:02.697",
  "references": [
    {
      "url": "https://jvn.jp/en/vu/JVNVU92808077/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://www.electronics.jtekt.co.jp/en/topics/202410026928/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://www.electronics.jtekt.co.jp/jp/topics/2024100217388/",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "vultures@jpcert.or.jp",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability exists in Kostac PLC Programming Software (Former name: Koyo PLC Programming Software) Version 1.6.14.0 and earlier. Having a user open a specially crafted project file which was saved using Kostac PLC Programming Software Version 1.6.9.0 and earlier may cause a denial-of-service (DoS) condition, arbitrary code execution, and/or information disclosure because the issues exist in parsing of KPP project files."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de desbordamiento de búfer basado en pila en el software de programación de PLC Kostac (nombre anterior: software de programación de PLC Koyo) versión 1.6.14.0 y anteriores. Si un usuario abre un archivo de proyecto especialmente manipulado que se guardó con el software de programación de PLC Kostac versión 1.6.9.0 y anteriores, puede provocar una condición de denegación de servicio (DoS), ejecución de código arbitrario o divulgación de información debido a que los problemas existen en el análisis de los archivos de proyecto de KPP."
    }
  ],
  "lastModified": "2026-06-17T07:56:36.340",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:jtekt:kostac_plc:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4D035F46-CBB8-40BD-B819-DB523E055234",
              "versionEndExcluding": "1.6.15.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp"
}