« Volver al listado

CVE-2024-44104

Estado: ModificadaAlta (7.8)—

An incorrectly implemented authentication scheme that is subjected to a spoofing attack in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0) allows a local authenticated attacker to escalate their privileges.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-44104",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-44104",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-11T00:00:00+00:00"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 2
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
      "affectedData": [
        {
          "vendor": "Ivanti",
          "product": "Workspace Control",
          "versions": [
            {
              "status": "unaffected",
              "version": "10.19.0.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "affected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*"
          ],
          "vendor": "ivanti",
          "product": "automation",
          "versions": [
            {
              "status": "unaffected",
              "version": "0",
              "lessThan": "10.18.99.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "affected"
        }
      ]
    }
  ],
  "published": "2024-09-10T21:15:13.727",
  "references": [
    {
      "url": "https://forums.ivanti.com/s/article/Security-Advisory-Ivanti-Workspace-Control-IWC",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-290"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An incorrectly implemented authentication scheme that is subjected to a spoofing attack in the management console of Ivanti Workspace Control before version 2025.2 (10.19.0.0)  allows a local authenticated attacker to escalate their privileges."
    },
    {
      "lang": "es",
      "value": "Un esquema de autenticación implementado incorrectamente que está sujeto a un ataque de suplantación de identidad en la consola de administración de Ivanti Workspace Control versión 10.18.0.0 y anteriores permite que un atacante autenticado local aumente sus privilegios."
    }
  ],
  "lastModified": "2026-06-17T07:52:18.963",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:ivanti:workspace_control:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "21D83B80-CA53-4122-864F-7CD27A212A4A",
              "versionEndExcluding": "10.18.99.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75"
}