CVE-2024-4235
Estado: AnalizadaMedia (4.9)—
A vulnerability classified as problematic was found in Netgear DG834Gv5 1.6.01.34. This vulnerability affects unknown code of the component Web Management Interface. The manipulation leads to cleartext storage of sensitive information. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-262126 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 4.9
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.56%
- Percentil entre todas las CVEs puntuadas: 45
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-312
Referencias
- https://netsecfish.notion.site/Netgear-DG834Gv5-Plain-Text-Credentials-Exposure-22e94fe066014490bebd349775d10b27?pvs=4
- https://vuldb.com/?ctiid.262126
- https://vuldb.com/?id.262126
- https://vuldb.com/?submit.319148
- https://netsecfish.notion.site/Netgear-DG834Gv5-Plain-Text-Credentials-Exposure-22e94fe066014490bebd349775d10b27?pvs=4
- https://vuldb.com/?ctiid.262126
- https://vuldb.com/?id.262126
- https://vuldb.com/?submit.319148
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-4235",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-4235",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-04-29T21:04:22.722401Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 3.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:N/A:N",
"authentication": "MULTIPLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "LOW",
"obtainAllPrivilege": false,
"exploitabilityScore": 6.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 2.7,
"attackVector": "NETWORK",
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "LOW"
},
"impactScore": 1.4,
"exploitabilityScore": 1.2
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.9,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Netgear",
"modules": [
"Web Management Interface"
],
"product": "DG834Gv5",
"versions": [
{
"status": "affected",
"version": "1.6.01.34"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:netgear:dg834gv5:-:*:*:*:*:*:*:*"
],
"vendor": "netgear",
"product": "dg834gv5",
"versions": [
{
"status": "affected",
"version": "1.6.01.34"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-26T18:15:46.527",
"references": [
{
"url": "https://netsecfish.notion.site/Netgear-DG834Gv5-Plain-Text-Credentials-Exposure-22e94fe066014490bebd349775d10b27?pvs=4",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.262126",
"tags": [
"Permissions Required",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.262126",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.319148",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://netsecfish.notion.site/Netgear-DG834Gv5-Plain-Text-Credentials-Exposure-22e94fe066014490bebd349775d10b27?pvs=4",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.262126",
"tags": [
"Permissions Required",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.262126",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?submit.319148",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-312"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Netgear DG834Gv5 1.6.01.34. This vulnerability affects unknown code of the component Web Management Interface. The manipulation leads to cleartext storage of sensitive information. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-262126 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Netgear DG834Gv5 1.6.01.34 y clasificada como problemática. Esta vulnerabilidad afecta a código desconocido del componente Web Management Interface. La manipulación conduce al almacenamiento en texto plano de información confidencial. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. VDB-262126 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
}
],
"lastModified": "2026-06-17T08:01:23.103",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:dg834gv5_firmware:1.6.01.34:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "7EA427BF-331A-46BC-9C67-3CFF3661C1BB"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:dg834gv5:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F92A4286-8696-4FC7-9D1D-4035E267770B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}