« Volver al listado

CVE-2024-42345

Estado: AnalizadaMedia (5.3)—

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session establishment and invalidation. This could allow a remote attacker to circumvent the additional multi factor authentication for user session establishment.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-42345",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-42345",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-10T14:53:27.296922Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 4.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
          "integrityImpact": "LOW",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 1.4,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 5.3,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "LOW",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "LOW",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "NONE",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEMA Remote Connect Server",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.2 SP2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-09-10T10:15:12.433",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-869574.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-384"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session establishment and invalidation. This could allow a remote attacker to circumvent the additional multi factor authentication for user session establishment."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones anteriores a V3.2 SP2). La aplicación afectada no gestiona correctamente el establecimiento y la invalidación de sesiones de usuario. Esto podría permitir que un atacante remoto eluda la autenticación multifactor adicional para el establecimiento de sesiones de usuario."
    }
  ],
  "lastModified": "2026-06-17T07:49:17.917",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BA2839E7-E397-4D69-865B-439F0017D540",
              "versionEndExcluding": "3.2"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6CBBACB4-9C5A-4616-BD70-FEDEE9978BFC"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:hf1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B9B79132-ECF2-4519-9D07-28DB6B0ABE2C"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:3.2:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A5A387A4-6899-4756-9EAA-ADBC636F8CF4"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}