« Volver al listado

CVE-2024-41940

Estado: AnalizadaCrítica (9.4)—

A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-41940",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-41940",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-13T14:21:02.771500Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 2.3
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 6,
        "exploitabilityScore": 2.3
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 9.4,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "HIGH",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC NMS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V3.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "sinec_nms",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "3.0",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-08-13T08:15:14.890",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones &lt; V3.0). La aplicación afectada no valida correctamente la entrada del usuario en una cola de comandos privilegiada. Esto podría permitir que un atacante autenticado ejecute comandos del sistema operativo con privilegios elevados."
    }
  ],
  "lastModified": "2026-06-17T07:48:29.613",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AE06B8AF-B36C-4743-A056-30712163F75B",
              "versionEndExcluding": "3.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}