CVE-2024-41908
Estado: AplazadaAlta (7.3)—
A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 7.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.18%
- Percentil entre todas las CVEs puntuadas: 7
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-41908",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-41908",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-08-13T13:29:47.094197Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 7.3,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "PASSIVE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "productcert@siemens.com",
"affectedData": [
{
"vendor": "Siemens",
"product": "NX",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2406.3000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:siemens:nx_1957_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:siemens:nx_1961_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:siemens:nx_1965_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:siemens:nx_1969_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:siemens:nx_1984_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:siemens:nx_1988_firmware:-:*:*:*:*:*:*:*"
],
"vendor": "siemens",
"product": "nx_1988_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "2406.3000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-08-13T08:15:14.110",
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-357412.html",
"source": "productcert@siemens.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "productcert@siemens.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en NX (Todas las versiones < V2406.3000). Las aplicaciones afectadas contienen una vulnerabilidad de lectura fuera de los límites al analizar archivos PRT especialmente manipulados. Esto podría permitir que un atacante bloquee la aplicación o ejecute código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T07:48:25.863",
"sourceIdentifier": "productcert@siemens.com"
}