« Volver al listado

CVE-2024-41716

Estado: ModificadaAlta (8.1)—

Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product's project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-41716",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-41716",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-04T13:58:55.637135Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "vultures@jpcert.or.jp",
      "affectedData": [
        {
          "vendor": "IDEC Corporation",
          "product": "WindLDR",
          "versions": [
            {
              "status": "affected",
              "version": "Ver.9.1.0 and earlier"
            }
          ]
        },
        {
          "vendor": "IDEC Corporation",
          "product": "WindO/I-NV4",
          "versions": [
            {
              "status": "affected",
              "version": "Ver.3.0.1"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-09-04T01:15:11.747",
  "references": [
    {
      "url": "https://jvn.jp/en/jp/JVN08342147/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://us.idec.com/media/24-RD-0219-EN.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cleartext storage of sensitive information vulnerability exists in WindLDR and WindO/I-NV4. If this vulnerability is exploited, an attacker who obtained the product's project file may obtain user credentials of the PLC or Operator Interfaces. As a result, an attacker may be able to manipulate and/or suspend the PLC and Operator Interfaces by accessing or hijacking them."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de almacenamiento de texto plano de información confidencial en WindLDR y WindO/I-NV4. Si se explota esta vulnerabilidad, un atacante que haya obtenido el archivo de proyecto del producto puede obtener las credenciales de usuario del PLC o las interfaces del operador. Como resultado, un atacante puede manipular y/o suspender el PLC y las interfaces del operador accediendo a ellos o secuestrándolos."
    }
  ],
  "lastModified": "2026-06-17T07:48:06.977",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:idec:windldr:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "3A8085E3-47BE-471B-9752-1B0B7482954B",
              "versionEndExcluding": "9.2.0"
            },
            {
              "criteria": "cpe:2.3:a:idec:windo\\/i-nv4:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2778FEF8-6239-40F4-8E1F-B9AEBA9711FD",
              "versionEndExcluding": "3.1.0"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp"
}