« Volver al listado

CVE-2024-4123

Estado: AnalizadaAlta (8.8)—

A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-4123",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-4123",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-04-29T18:27:25.556651Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Tenda",
          "product": "W15E",
          "versions": [
            {
              "status": "affected",
              "version": "15.11.0.14"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-04-24T19:15:47.317",
  "references": [
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetPortMapping.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.261866",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.261866",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?submit.317828",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formSetPortMapping.md",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?ctiid.261866",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.261866",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?submit.317828",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Tenda W15E 15.11.0.14 y clasificada como crítica. La función formSetPortMapping del archivo /goform/SetPortMapping es afectada por esta vulnerabilidad. La manipulación del argumento portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal conduce a un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. VDB-261866 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
    }
  ],
  "lastModified": "2026-06-17T08:01:10.880",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DBEDB6F7-0043-491C-919E-23C8DA89256A"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "248A1A83-1288-42D8-A9BC-13D3AA7A2881"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}