CVE-2024-4116
Estado: AnalizadaAlta (8.8)—
A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.68%
- Percentil entre todas las CVEs puntuadas: 76
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-121
- CWE-787
Referencias
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md
- https://vuldb.com/?ctiid.261859
- https://vuldb.com/?id.261859
- https://vuldb.com/?submit.317819
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md
- https://vuldb.com/?ctiid.261859
- https://vuldb.com/?id.261859
- https://vuldb.com/?submit.317819
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-4116",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-4116",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-07-17T13:31:11.940050Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 9,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"authentication": "SINGLE",
"integrityImpact": "COMPLETE",
"accessComplexity": "LOW",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "HIGH",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "Tenda",
"product": "W15E",
"versions": [
{
"status": "affected",
"version": "15.11.0.14"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*"
],
"vendor": "tenda",
"product": "w15e",
"versions": [
{
"status": "affected",
"version": "15.11.0.14"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-24T16:15:10.347",
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.261859",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.261859",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?submit.317819",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.261859",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.261859",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?submit.317819",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido encontrada en Tenda W15E 15.11.0.14 y clasificada como crítica. La función formDelDhcpRule del archivo /goform/DelDhcpRule es afectada por esta vulnerabilidad. La manipulación del argumento delDhcpIndex provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-261859. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera. "
}
],
"lastModified": "2026-06-17T08:01:09.813",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "DBEDB6F7-0043-491C-919E-23C8DA89256A"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "248A1A83-1288-42D8-A9BC-13D3AA7A2881"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}