« Volver al listado

CVE-2024-4111

Estado: AnalizadaAlta (8.8)—

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-4111",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-4111",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-04-29T18:30:42.968664Z"
        }
      }
    ],
    "cvssMetricV2": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "authentication": "SINGLE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cna@vuldb.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cna@vuldb.com",
      "affectedData": [
        {
          "vendor": "Tenda",
          "product": "TX9",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-04-24T14:15:45.713",
  "references": [
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md",
      "tags": [
        "Broken Link"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?ctiid.261854",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?id.261854",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://vuldb.com/?submit.317205",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "cna@vuldb.com"
    },
    {
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/TX9/SetLEDCfg.md",
      "tags": [
        "Broken Link"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?ctiid.261854",
      "tags": [
        "Permissions Required",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?id.261854",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://vuldb.com/?submit.317205",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cna@vuldb.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Se encontró una vulnerabilidad en Tenda TX9 22.03.02.10. Ha sido calificado como crítico. La función sub_42BD7C del archivo /goform/SetLEDCfg es afectada por esta vulnerabilidad. La manipulación del tiempo del argumento conduce a un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al público y puede utilizarse. VDB-261854 es el identificador asignado a esta vulnerabilidad. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."
    }
  ],
  "lastModified": "2026-06-17T08:01:09.137",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:tx9_pro_firmware:22.03.02.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4D7650EF-9C51-400B-96A8-342D1DF8A601"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:tx9_pro:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "086A4597-3A8E-4F94-98A8-D31C46453E15"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com"
}