CVE-2024-39882
Estado: ModificadaAlta (8.4)—
Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 8.4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.70%
- Percentil entre todas las CVEs puntuadas: 51
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-39882",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-39882",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-07-23T18:55:11.251122Z"
}
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.4,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "ACTIVE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "ics-cert@hq.dhs.gov",
"affectedData": [
{
"vendor": "Delta Electronics",
"product": "CNCSoft-G2",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:delta_electronics:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*"
],
"vendor": "delta_electronics",
"product": "cncsoft-g2",
"versions": [
{
"status": "affected",
"version": "2.0.0.5"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-07-09T22:15:03.013",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "ics-cert@hq.dhs.gov"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-191-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "ics-cert@hq.dhs.gov",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics CNCSoft-G2 lacks proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Delta Electronics CNCSoft-G2 carece de una validación adecuada de los datos proporcionados por el usuario, lo que puede provocar una lectura más allá del final de un búfer asignado. Si un objetivo visita una página maliciosa o abre un archivo malicioso, un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual."
}
],
"lastModified": "2026-06-17T07:42:57.737",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:deltaww:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "023EB74A-5EBD-489D-BA0F-CF4ED45EECB9"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov"
}