« Volver al listado

CVE-2024-37997

Estado: AplazadaAlta (7.3)—

A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-37997",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-37997",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-07-09T13:19:33.793225Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.3,
          "Automatable": "NOT_DEFINED",
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "PASSIVE",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "JT Open",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "JT2Go",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2406.0003",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "PLM XML SDK",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V7.1.0.014",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V14.2",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V14.2.0.13",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V14.3",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V14.3.0.11",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2312",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2312.0008",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2406",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2406.0003",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:siemens:jt_open:*:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "jt_open",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V11.5",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "cpes": [
            "cpe:2.3:a:siemens:plm_xml_sdk:v7.1.0.0014:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "plm_xml_sdk",
          "versions": [
            {
              "status": "affected",
              "version": "V7.1.0.014"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-07-09T12:15:15.280",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-959281.html",
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-824889.html",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en JT Open (todas las versiones &lt; V11.5), PLM XML SDK (todas las versiones &lt; V7.1.0.014). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria al analizar archivos XML especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."
    }
  ],
  "lastModified": "2026-06-17T07:39:11.763",
  "sourceIdentifier": "productcert@siemens.com"
}