« Volver al listado

CVE-2024-37991

Estado: AnalizadaMedia (6)—

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2).

Leer descripción completaMostrar menos

The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (27)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-37991",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-37991",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-10T15:09:26.404268Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 5.3,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "HIGH",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 1.6
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "integrityImpact": "NONE",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 3.6,
        "exploitabilityScore": 2.8
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 6,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "PASSIVE",
          "attackComplexity": "HIGH",
          "attackRequirements": "NONE",
          "privilegesRequired": "NONE",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "NONE",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF610R CMIIT",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF610R ETSI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF610R FCC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF615R CMIIT",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF615R ETSI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF615R FCC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF650R ARIB",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF650R CMIIT",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF650R ETSI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF650R FCC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF680R ARIB",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF680R CMIIT",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF680R ETSI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF680R FCC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF685R ARIB",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF685R CMIIT",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF685R ETSI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC Reader RF685R FCC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V4.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF1140R",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V1.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF1170R",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V1.1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF166C",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF185C",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF186C",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF186CI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF188C",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF188CI",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC RF360R",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.2",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-09-10T10:15:10.600",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (Todas las versiones &lt; V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (Todas las versiones &lt; V4.2), SIMATIC RF1140R (6GT2831-6CB00) (Todas las versiones &lt; V1.1), SIMATIC RF1170R (6GT2831-6BB00) (Todas las versiones &lt; V1.1), SIMATIC RF166C (6GT2002-0EE20) (Todas las versiones &lt; V2.2), SIMATIC RF185C (6GT2002-0JE10) (Todas las versiones &lt; V2.2), SIMATIC RF186C (6GT2002-0JE20) (Todas las versiones &lt; V2.2), SIMATIC RF186CI (6GT2002-0JE50) (Todas las versiones &lt; V2.2), SIMATIC RF188C (6GT2002-0JE40) (Todas las versiones &lt; V2.2), SIMATIC RF188CI (6GT2002-0JE60) (Todas las versiones &lt; V2.2), SIMATIC RF360R (6GT2801-5BA30) (Todas las versiones &lt; V2.2). Se puede acceder a los archivos de registro de servicio de la aplicación afectada sin la autenticación adecuada. Esto podría permitir que un atacante no autenticado obtenga acceso a información confidencial."
    }
  ],
  "lastModified": "2026-06-17T07:39:10.640",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D8930F2B-7C37-4059-85FC-0316B631C860",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf1170r_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CC216594-D56B-454D-BD2C-50631B8C8F9C",
              "versionEndExcluding": "1.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf1170r:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "DD8AD128-F6E2-45BD-9098-EC559D193194"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf1140r_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "11F4F714-F802-4D13-A965-0A22B80DA9D0",
              "versionEndExcluding": "1.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf1140r:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1EA20BB5-024E-4389-A0FE-C218E15D31A8"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "F61801B9-80FD-45EC-9A20-5C703CB8BE76",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "76F5073F-CAE9-4071-9C86-2B29FB529A49"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "058EDB3A-31B8-482F-B825-B0A7E192356E",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D00C8A81-53EB-425F-A730-AC7505285B73"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "62FC4D21-B225-4349-A8E8-68780CC465D1",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B3C8FC67-825D-4E55-8341-E449EA98B6AD"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1E84B475-1FB7-4BF1-880B-8DB5137BB941",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BFAA7370-1B78-4AF8-8358-830460A5E81C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "970B3705-6172-4C00-B402-30A7F23C5A08",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "40D5F6C3-3AC5-40F2-B755-130E24169AB3"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7D261FBC-1E4C-4016-AD0E-F234EE36F09A",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "08729226-19DB-410A-A764-B84E5213839D"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B5B465BD-D425-44C7-931C-E6DAABB79B67",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EA13A689-EBB3-47D3-83AB-4EAFCB0CCF14"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C1B9A6C1-E7AD-46DE-A0EC-E6E03B957A13",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "CC372090-E9D1-4CB7-8CDC-8FA439764359"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6BBDF6C6-A67A-412F-8ACF-27E3AA0EE8E9",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "EFD9ED6C-B948-4F73-ADC9-2EA7AFB646C9"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "28C49CB8-179A-47B7-9B04-FC214382B643",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "70C73C18-EC1D-431A-808F-1C16706B7F26"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "896E8488-0AB0-4C39-9729-1E42F4C28419",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "838474F2-85A2-4315-8F0C-B1AAC9B20373"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E525612D-8273-42FD-8DAD-D589ED61C9D6",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5735D69B-EBA4-4ADD-9D02-AFFBDB14B085"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "130361E8-6979-492F-89A3-4EFFF8F5379F",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "557BB258-1B9D-457F-9573-85439950C361"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "DC98A393-C374-4411-94FE-9832CD8690ED",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C951AC92-DD7E-4C24-BC38-1D041D81691C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2AA399AA-B0C4-48D5-B5F5-EE7A65D10A95",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C4C96D63-0711-48F8-ADE2-261FCF306049"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C902FA6A-3E5D-471C-8513-27FE8BB5B2DC",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "F85BC978-9C30-4484-B6D7-B7A4543EFDA5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA5DA457-347E-4B6B-8003-882BD4D95D64",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E0BFFE2B-5843-4A03-A6A7-1098A4FB9A0C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B07B2FDF-E6A5-4E06-9328-01F311E85AF9",
              "versionEndExcluding": "4.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "C3CE2417-B29E-4CBD-9A30-3DB5C30771D5"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "84F1472B-A584-4712-BEF7-7B4BDE166CE2",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D7DB4915-E989-4085-B201-C5CCC86AB924",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B280EE0D-F3F9-46E3-949F-109844428C35",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E86AC831-9FB9-4D17-AA06-E68C176F1A23",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1A27B28F-A037-4730-A0DD-96BB568F4A58",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D48EE1B0-3010-44F2-AEF9-A3E35BD03971",
              "versionEndExcluding": "2.2"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}