CVE-2024-37037
Estado: ModificadaAlta (8.1)—
CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
- Puntuación base: 8.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.03%
- Percentil entre todas las CVEs puntuadas: 62
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-37037",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-37037",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-06-12T18:28:51.967522Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.1,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "NONE"
},
"impactScore": 5.2,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cybersecurity@se.com",
"affectedData": [
{
"vendor": "Schneider Electric",
"product": "Sage 1410",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Sage 1430",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Sage 1450",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Sage 2400",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Sage 3030 Magnum",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Schneider Electric",
"product": "Sage 4400",
"versions": [
{
"status": "affected",
"version": "Versions C3414-500-S02K5_P8 and prior"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
],
"vendor": "schneider-electric",
"product": "sage_4400",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "c3414-500-s02k5_p8"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-06-12T17:15:50.853",
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "cybersecurity@se.com"
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf",
"tags": [
"Patch",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cybersecurity@se.com",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
},
{
"lang": "es",
"value": "CWE-22: Existe una vulnerabilidad de limitación inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") que podría permitir que un usuario autenticado con acceso a la interfaz web del dispositivo corrompa archivos y afecte la funcionalidad del dispositivo al enviar una solicitud HTTP manipulada."
}
],
"lastModified": "2026-06-17T07:37:38.887",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D4DDD3DD-576C-404E-A132-D1357936A610",
"versionEndExcluding": "c3414-500-s02k5_p9"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "02E606BD-92F8-4396-AD13-666D76E1E34D"
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "97E29CCC-4E21-411E-80DD-545A66E9B042"
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "66759867-027F-4FA6-ABA6-BFDEE49E8F8D"
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "AA561E2A-4787-48D7-ABBB-26D0D7D24E6F"
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "453696F2-0F4C-4000-A438-F814D0FC3504"
},
{
"criteria": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "6462B366-8F9F-49D6-939A-E73C1D5A707C"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cybersecurity@se.com"
}