Estado: ModificadaAlta (8.1)—

CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path Traversal’) vulnerability exists that could allow an authenticated user with access to the device’s web interface to corrupt files and impact device functionality when sending a crafted HTTP request.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-37037",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-37037",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-06-12T18:28:51.967522Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "cybersecurity@se.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.1,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cybersecurity@se.com",
      "affectedData": [
        {
          "vendor": "Schneider Electric",
          "product": "Sage 1410",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Sage 1430",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Sage 1450",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Sage 2400",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Sage 3030 Magnum",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Schneider Electric",
          "product": "Sage 4400",
          "versions": [
            {
              "status": "affected",
              "version": "Versions C3414-500-S02K5_P8 and prior"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
            "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
            "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
            "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
            "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
            "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*"
          ],
          "vendor": "schneider-electric",
          "product": "sage_4400",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "versionType": "custom",
              "lessThanOrEqual": "c3414-500-s02k5_p8"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2024-06-12T17:15:50.853",
  "references": [
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "cybersecurity@se.com"
    },
    {
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-05.pdf",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "cybersecurity@se.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (‘Path\nTraversal’) vulnerability exists that could allow an authenticated user with access to the device’s\nweb interface to corrupt files and impact device functionality when sending a crafted HTTP\nrequest."
    },
    {
      "lang": "es",
      "value": "CWE-22: Existe una vulnerabilidad de limitación inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") que podría permitir que un usuario autenticado con acceso a la interfaz web del dispositivo corrompa archivos y afecte la funcionalidad del dispositivo al enviar una solicitud HTTP manipulada."
    }
  ],
  "lastModified": "2026-06-17T07:37:38.887",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:sage_rtu_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D4DDD3DD-576C-404E-A132-D1357936A610",
              "versionEndExcluding": "c3414-500-s02k5_p9"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "02E606BD-92F8-4396-AD13-666D76E1E34D"
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "97E29CCC-4E21-411E-80DD-545A66E9B042"
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "66759867-027F-4FA6-ABA6-BFDEE49E8F8D"
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "AA561E2A-4787-48D7-ABBB-26D0D7D24E6F"
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "453696F2-0F4C-4000-A438-F814D0FC3504"
            },
            {
              "criteria": "cpe:2.3:h:schneider-electric:sage_4400:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "6462B366-8F9F-49D6-939A-E73C1D5A707C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com"
}