CVE-2024-33607
Estado: AnalizadaMedia (5.7)—
Out-of-bounds read in some Intel(R) TDX module software before version TDX_1.5.07.00.774 may allow an authenticated user to potentially enable information disclosure via local access.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 5.7
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.13%
- Percentil entre todas las CVEs puntuadas: 2
- Fecha de la puntuación: 1/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-125
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-33607",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-33607",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-08-13T19:54:29.982337Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "secure@intel.com",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 5.6,
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 4,
"exploitabilityScore": 1.1
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "secure@intel.com",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 5.7,
"Automatable": "NOT_DEFINED",
"attackVector": "LOCAL",
"baseSeverity": "MEDIUM",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "secure@intel.com",
"affectedData": [
{
"vendor": "n/a",
"product": "Intel(R) TDX module software",
"versions": [
{
"status": "affected",
"version": "before version TDX_1.5.07.00.774"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-08-12T17:15:27.167",
"references": [
{
"url": "https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01192.html",
"tags": [
"Vendor Advisory"
],
"source": "secure@intel.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "secure@intel.com",
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Out-of-bounds read in some Intel(R) TDX module software before version TDX_1.5.07.00.774 may allow an authenticated user to potentially enable information disclosure via local access."
},
{
"lang": "es",
"value": "La lectura fuera de los límites en algún software del módulo Intel(R) TDX anterior a la versión TDX_1.5.07.00.774 puede permitir que un usuario autenticado habilite potencialmente la divulgación de información a través del acceso local."
}
],
"lastModified": "2026-08-31T13:37:56.760",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:tdx_module:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CBEFE231-F122-47F4-B492-3B787F7A5ED0",
"versionEndExcluding": "1.5.07.00.774"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "secure@intel.com"
}