« Volver al listado

CVE-2024-28812

Estado: AnalizadaAlta (8.8)—

An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-28812",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-28812",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-09-30T18:39:00.558124Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:infinera:hit_7300:*:*:*:*:*:*:*:*"
          ],
          "vendor": "infinera",
          "product": "hit_7300",
          "versions": [
            {
              "status": "affected",
              "version": "5.60.50"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-09-30T19:15:04.130",
  "references": [
    {
      "url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28812",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "cve@mitre.org"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Infinera hiT 7300 5.60.50. A hidden SSH service (on the local management network interface) with hardcoded credentials allows attackers to access the appliance operating system (with highest privileges) via an SSH connection."
    },
    {
      "lang": "es",
      "value": "Se descubrió un problema en Infinera hiT 7300 5.60.50. Un servicio SSH oculto (en la interfaz de red de administración local) con credenciales codificadas permite a los atacantes acceder al sistema operativo del dispositivo (con los privilegios más altos) a través de una conexión SSH."
    }
  ],
  "lastModified": "2026-06-17T07:21:50.007",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:nokia:hit_7300_firmware:5.60.50:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2979EC9B-73BA-442D-868B-EA73EB1C6D02"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:nokia:hit_7300:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "0EE3136D-4DFE-43F7-AE1F-62A9D3F77349"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}