CVE-2024-28809
Estado: AnalizadaAlta (8.8)—
An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.17%
- Percentil entre todas las CVEs puntuadas: 6
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-312, CWE-798
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-28809",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-28809",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-09-30T20:50:50.976160Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "ADJACENT_NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:infinera:hit_7300:5.60.50:*:*:*:*:*:*:*"
],
"vendor": "infinera",
"product": "hit_7300",
"versions": [
{
"status": "affected",
"version": "5.60.50"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-09-30T18:15:05.633",
"references": [
{
"url": "https://www.cvcn.gov.it/cvcn/cve/CVE-2024-28809",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-312"
},
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Infinera hiT 7300 5.60.50. Cleartext storage of sensitive password in firmware update packages allows attackers to access various appliance services via hardcoded credentials."
},
{
"lang": "es",
"value": "Se descubrió un problema en Infinera hiT 7300 5.60.50. El almacenamiento en texto plano de contraseñas confidenciales en paquetes de actualización de firmware permite a los atacantes acceder a varios servicios del dispositivo mediante credenciales codificadas."
}
],
"lastModified": "2026-06-17T07:21:49.520",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nokia:hit_7300_firmware:5.60.50:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2979EC9B-73BA-442D-868B-EA73EB1C6D02"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nokia:hit_7300:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "0EE3136D-4DFE-43F7-AE1F-62A9D3F77349"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve@mitre.org"
}