CVE-2024-28162
Estado: AnalizadaMedia (4.2)—
In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N
- Puntuación base: 4.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.34%
- Percentil entre todas las CVEs puntuadas: 25
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-295
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-28162",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-28162",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-03-07T16:28:35.423603Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 4.2,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.5,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "jenkinsci-cert@googlegroups.com",
"affectedData": [
{
"vendor": "Jenkins Project",
"product": "Jenkins Delphix Plugin",
"versions": [
{
"status": "affected",
"version": "3.0.1",
"versionType": "maven",
"lessThanOrEqual": "3.1.0"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-03-06T17:15:11.140",
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2024/03/06/3",
"tags": [
"Mailing List"
],
"source": "jenkinsci-cert@googlegroups.com"
},
{
"url": "https://www.jenkins.io/security/advisory/2024-03-06/#SECURITY-3330",
"tags": [
"Vendor Advisory"
],
"source": "jenkinsci-cert@googlegroups.com"
},
{
"url": "http://www.openwall.com/lists/oss-security/2024/03/06/3",
"tags": [
"Mailing List"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.jenkins.io/security/advisory/2024-03-06/#SECURITY-3330",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"description": [
{
"lang": "en",
"value": "CWE-295"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Jenkins Delphix Plugin 3.0.1 through 3.1.0 (both inclusive) a global option for administrators to enable or disable SSL/TLS certificate validation for Data Control Tower (DCT) connections fails to take effect until Jenkins is restarted when switching from disabled validation to enabled validation."
},
{
"lang": "es",
"value": "En Jenkins Delphix Plugin 3.0.1 a 3.1.0 (ambos inclusive), una opción global para que los administradores habiliten o deshabiliten la validación de certificados SSL/TLS para conexiones de la Torre de control de datos (DCT) no surte efecto hasta que se reinicia al cambiar de validación deshabilitada a validación habilitada."
}
],
"lastModified": "2026-06-17T07:21:07.263",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:jenkins:delphix:*:*:*:*:*:jenkins:*:*",
"vulnerable": true,
"matchCriteriaId": "3DE811F3-62AA-4BDB-BA19-CFD6D0CFC35B",
"versionEndExcluding": "3.1.1",
"versionStartIncluding": "3.0.1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "jenkinsci-cert@googlegroups.com"
}