CVE-2024-27263
Estado: AnalizadaMedia (5.3)—
IBM Sterling B2B Integrator 6.0.0.0 through 6.1.2.5 and 6.2.0.0 through 6.2.0.1 could allow an authenticated user to obtain sensitive information from the dashboard UI using man in the middle techniques.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
- Puntuación base: 5.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.27%
- Percentil entre todas las CVEs puntuadas: 18
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-300
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-27263",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-27263",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-01-28T14:53:24.496953Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "HIGH",
"availabilityImpact": "NONE",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 3.6,
"exploitabilityScore": 1.6
}
]
},
"affected": [
{
"source": "psirt@us.ibm.com",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:ibm:sterling_b2b_integrator:6.0.0.0:*:*:*:standard:*:*:*",
"cpe:2.3:a:ibm:sterling_b2b_integrator:6.1.2.5:*:*:*:standard:*:*:*",
"cpe:2.3:a:ibm:sterling_b2b_integrator:6.2.0.0:*:*:*:standard:*:*:*",
"cpe:2.3:a:ibm:sterling_b2b_integrator:6.2.0.1:*:*:*:standard:*:*:*"
],
"vendor": "IBM",
"product": "Sterling B2B Integrator",
"versions": [
{
"status": "affected",
"version": "6.0.0.0",
"versionType": "semver",
"lessThanOrEqual": "6.1.2.5"
},
{
"status": "affected",
"version": "6.2.0.0",
"versionType": "semver",
"lessThanOrEqual": "6.2.0.1"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2025-01-28T01:15:08.950",
"references": [
{
"url": "https://www.ibm.com/support/pages/node/7176072",
"tags": [
"Vendor Advisory"
],
"source": "psirt@us.ibm.com"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt@us.ibm.com",
"description": [
{
"lang": "en",
"value": "CWE-300"
}
]
},
{
"type": "Secondary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "IBM Sterling B2B Integrator 6.0.0.0 through 6.1.2.5 and 6.2.0.0 through 6.2.0.1 could allow an authenticated user to obtain sensitive information from the dashboard UI using man in the middle techniques."
},
{
"lang": "es",
"value": "IBM Sterling B2B Integrator 6.0.0.0 a 6.1.2.5 y 6.2.0.0 a 6.2.0.1 podrían permitir que un usuario autenticado obtenga información confidencial de la interfaz de usuario del panel de control mediante técnicas de intermediario."
}
],
"lastModified": "2026-06-17T07:19:32.193",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ibm:sterling_b2b_integrator:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E2DD03C2-67D3-4BA5-8109-10C84538AC3B",
"versionEndIncluding": "6.1.2.5",
"versionStartIncluding": "6.0.0.0"
},
{
"criteria": "cpe:2.3:a:ibm:sterling_b2b_integrator:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "ECA7E00E-2AD1-4AA7-BAA8-3E8A14F48D21",
"versionEndIncluding": "6.2.0.1",
"versionStartIncluding": "6.2.0.0"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "psirt@us.ibm.com"
}