« Volver al listado

CVE-2024-25679

Estado: ModificadaMedia (6.5)—

In PQUIC before 5bde5bb, retention of unused initial encryption keys allows attackers to disrupt a connection with a PSK configuration by sending a CONNECTION_CLOSE frame that is encrypted via the initial key computed. Network traffic sniffing is needed as part of exploitation.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-25679",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-25679",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-02-09T16:59:56.624207Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 2.2
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 6.5,
          "attackVector": "NETWORK",
          "baseSeverity": "MEDIUM",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:L",
          "integrityImpact": "NONE",
          "userInteraction": "NONE",
          "attackComplexity": "HIGH",
          "availabilityImpact": "LOW",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 4.2,
        "exploitabilityScore": 2.2
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-02-09T10:15:08.740",
  "references": [
    {
      "url": "https://github.com/p-quic/pquic/issues/35",
      "tags": [
        "Issue Tracking"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/p-quic/pquic/pull/39",
      "tags": [
        "Patch"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://www.rfc-editor.org/rfc/rfc9001#name-discarding-unused-keys",
      "tags": [
        "Not Applicable"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "https://github.com/p-quic/pquic/issues/35",
      "tags": [
        "Issue Tracking"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://github.com/p-quic/pquic/pull/39",
      "tags": [
        "Patch"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.rfc-editor.org/rfc/rfc9001#name-discarding-unused-keys",
      "tags": [
        "Not Applicable"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-324"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "In PQUIC before 5bde5bb, retention of unused initial encryption keys allows attackers to disrupt a connection with a PSK configuration by sending a CONNECTION_CLOSE frame that is encrypted via the initial key computed. Network traffic sniffing is needed as part of exploitation."
    },
    {
      "lang": "es",
      "value": "En PQUIC anterior a 5bde5bb, la retención de claves de cifrado iniciales no utilizadas permite a los atacantes interrumpir una conexión con una configuración PSK enviando una trama CONNECTION_CLOSE cifrada mediante la clave inicial calculada. La detección del tráfico de red es necesaria como parte de la explotación."
    }
  ],
  "lastModified": "2026-06-17T07:16:24.650",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:pquic:pquic:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9501E20C-7EEC-4218-83B2-1B7542857491",
              "versionEndExcluding": "2023-10-30"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}