« Volver al listado

CVE-2024-24923

Estado: ModificadaAlta (7.8)—

A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-24923",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-24923",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-02-13T14:54:00.777463Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2401.0000",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2306.0001",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-02-13T09:15:51.130",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-000072.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-000072.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000), Simcenter Femap (All versions < V2306.0001). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted Catia MODEL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22055)"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Simcenter Femap (Todas las versiones &lt; V2401.0000), Simcenter Femap (Todas las versiones &lt; V2306.0001). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada mientras analizan archivos Catia MODEL especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-22055)"
    }
  ],
  "lastModified": "2026-06-17T07:15:14.097",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA4B26BD-CF8A-46C4-A7E3-59BDE152FC59",
              "versionEndExcluding": "2306.0001"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}