CVE-2024-2424
Estado: AnalizadaAlta (7.5)—
An input validation vulnerability exists in the Rockwell Automation 5015-AENFTXT that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 2.61%
- Percentil entre todas las CVEs puntuadas: 85
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-20
- NVD-CWE-noinfo
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-2424",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-2424",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-04-19T17:11:22.359775Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "PSIRT@rockwellautomation.com",
"affectedData": [
{
"vendor": "Rockwell Automation ",
"product": "5015-AENFTXT",
"versions": [
{
"status": "affected",
"version": "v35"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:5015_aenftxt:v35:*:*:*:*:*:*:*"
],
"vendor": "rockwellautomation",
"product": "5015_aenftxt",
"versions": [
{
"status": "affected",
"version": "v35"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-15T22:15:08.657",
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"source": "PSIRT@rockwellautomation.com"
},
{
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "PSIRT@rockwellautomation.com",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "\nAn input validation vulnerability exists in the Rockwell Automation 5015-AENFTXT that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability. \n\n"
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de validación de entrada en Rockwell Automation 5015-AENFTXT que hace que el adaptador secundario genere una falla mayor no recuperable (MNRF) cuando se ingresa una entrada maliciosa. Si se explota, la disponibilidad del dispositivo se verá afectada y será necesario reiniciarlo manualmente. Además, se necesita un paquete PTP con formato incorrecto para aprovechar esta vulnerabilidad."
}
],
"lastModified": "2026-06-17T07:24:30.560",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:5015-aenftxt_firmware:2.011:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "436F7BB7-A8CA-4E00-9F42-6DDB0D995E09"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:5015-aenftxt:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C699B471-D2E4-4B2F-B0A4-6045B8170354"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com"
}