« Volver al listado

CVE-2024-23812

Estado: ModificadaAlta (8.8)—

A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-23812",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-23812",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-16T19:09:40.944691Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "productcert@siemens.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8,
          "attackVector": "ADJACENT_NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.1
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 8.8,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "productcert@siemens.com",
      "affectedData": [
        {
          "vendor": "Siemens",
          "product": "SINEC NMS",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "V2.0 SP1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*"
          ],
          "vendor": "siemens",
          "product": "sinec_nms",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "2.0SP1",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-02-13T09:15:49.953",
  "references": [
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-943925.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "productcert@siemens.com"
    },
    {
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-943925.html",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "productcert@siemens.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones &lt; V2.0 SP1). La aplicación afectada neutraliza incorrectamente elementos especiales al crear un informe, lo que podría dar lugar a la inyección de comandos."
    }
  ],
  "lastModified": "2026-06-17T07:13:39.153",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A7F0A543-38E1-48B9-A984-259081E49EAA",
              "versionEndExcluding": "2.0"
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:2.0:-:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "631E4756-904C-4B57-A991-76BA59D7B901"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "productcert@siemens.com"
}