« Volver al listado

CVE-2024-23786

Estado: ModificadaCrítica (9.3)—

Cross-site scripting vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary script on the web browser of the user who is accessing the management page of the affected product.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (2)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-23786",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-23786",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-03-18T13:46:28.975570Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.3,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.8,
        "exploitabilityScore": 2.8
      },
      {
        "type": "Secondary",
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "cvssData": {
          "scope": "CHANGED",
          "version": "3.1",
          "baseScore": 9.3,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:N",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "NONE",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.8,
        "exploitabilityScore": 2.8
      }
    ]
  },
  "affected": [
    {
      "source": "vultures@jpcert.or.jp",
      "affectedData": [
        {
          "vendor": "SHARP CORPORATION",
          "product": "Energy Management Controller with Cloud Services",
          "versions": [
            {
              "status": "affected",
              "version": "JH-RVB1 Ver.B0.1.9.1 and earlier"
            }
          ]
        },
        {
          "vendor": "SHARP CORPORATION",
          "product": "Energy Management Controller with Cloud Services",
          "versions": [
            {
              "status": "affected",
              "version": "JH-RV11 Ver.B0.1.9.1 and earlier"
            }
          ]
        }
      ]
    }
  ],
  "published": "2024-02-14T10:15:08.727",
  "references": [
    {
      "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://jvn.jp/en/vu/JVNVU94591337/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "vultures@jpcert.or.jp"
    },
    {
      "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://jvn.jp/en/vu/JVNVU94591337/",
      "tags": [
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary script on the web browser of the user who is accessing the management page of the affected product."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de Cross-Site Scripting en Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores permite que un atacante no autenticado adyacente a la red ejecute un script arbitrario en el navegador web del usuario que accede la página de gestión del producto afectado."
    }
  ],
  "lastModified": "2026-06-17T07:13:35.767",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B7EC16DF-21FB-473F-8F62-DDBF1C149A9B",
              "versionEndIncluding": "b0.1.9.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sharp:jh-rvb1:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "27ED2F7C-C3F1-41AA-81DA-3CD5C3B83F88"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E0A2340C-A0BC-4DD5-A120-F7041D76D776",
              "versionEndIncluding": "b0.1.9.1"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sharp:jh-rv11:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "9CF83BDB-56B1-4E80-91C3-AFAA96A0C25C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "vultures@jpcert.or.jp"
}