Estado: AnalizadaCrítica (9.1)—

A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (6)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-22187",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-22187",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "poc"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-05-28T19:27:50.593768Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "talos-cna@cisco.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 9.1,
          "attackVector": "NETWORK",
          "baseSeverity": "CRITICAL",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "NONE"
        },
        "impactScore": 5.2,
        "exploitabilityScore": 3.9
      }
    ]
  },
  "affected": [
    {
      "source": "talos-cna@cisco.com",
      "affectedData": [
        {
          "vendor": "AutomationDirect",
          "product": "P3-550E",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.10.9"
            }
          ]
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:h:automationdirect:p3-550e:1.2.10.9:*:*:*:*:*:*:*"
          ],
          "vendor": "automationdirect",
          "product": "p3-550e",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.10.9"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-05-28T16:15:12.330",
  "references": [
    {
      "url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003yXV2AY/sa00036",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1940",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1940",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "talos-cna@cisco.com"
    },
    {
      "url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003yXV2AY/sa00036",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1940",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1940",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "talos-cna@cisco.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ]
    },
    {
      "type": "Secondary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de escritura en qué lugar en la funcionalidad de diagnóstico de memoria remota de conexión de software de programación de AutomationDirect P3-550E 1.2.10.9. Un paquete de red especialmente manipulado puede provocar una escritura arbitraria. Un atacante puede enviar un paquete no autenticado para desencadenar esta vulnerabilidad."
    }
  ],
  "lastModified": "2026-06-17T07:10:53.760",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:1.2.10.9:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4A393F14-3BD3-44DE-B06F-9235AB62C68F"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5A4772E7-8788-4DB5-98CE-25F0255E0386"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p3-550e:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "5086EF1F-C3CE-4B5F-A352-67CE332A6C4F"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:1.2.10.9:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "CC227F17-D280-4C74-A73E-8F92158686BE"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5CC4A2E2-DF6D-427A-88E6-54FD6D11BDFC"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p3-550:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "BB4DDF3B-AB0E-4DDD-9865-D4EEDCCA78DE"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:1.2.10.9:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0462A9CE-4EAA-4C12-9147-F530C42328D3"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "C8277A48-94C7-40F3-A822-F6311B2CDA94"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p3-530:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "D58D4140-C719-4EDA-8963-667F9FF21970"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "AAF96AFD-40E3-4FB6-BAD7-067D9E257A08"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "D476CC45-B4A1-4210-9347-9854BB0A86AA"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p2-550:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "386D70E8-70D6-4D25-818C-2218E1B1AC6C"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "9B7F3A1F-BD96-49A7-A340-0E5E1893326C"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "27710A58-507C-43BB-849F-7238F5D6D9ED"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p1-550:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "8FAF2C99-BC5F-4E99-A3A8-FBBDDC24C933"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:1.2.10.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "01C6DFFC-374B-4314-9230-53BD01BD6574"
            },
            {
              "criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:4.1.1.10:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "51095762-A87C-4A1D-A4E2-679462DC8FA9"
            }
          ],
          "operator": "OR"
        },
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:p1-540:-:*:*:*:*:*:*:*",
              "vulnerable": false,
              "matchCriteriaId": "4DB6B9FC-390E-43FD-9DF9-AAB1A9CDAA48"
            }
          ],
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com"
}