An arbitrary code execution vulnerability in Rockwell Automation Arena Simulation could let a malicious user insert unauthorized code into the software. This is done by writing beyond the designated memory area, which causes an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-21912",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-21912",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2024-08-05T16:38:18.444663Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "PSIRT@rockwellautomation.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      },
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.8,
          "attackVector": "LOCAL",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "REQUIRED",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.8
      }
    ]
  },
  "affected": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "affectedData": [
        {
          "vendor": "Rockwell Automation",
          "product": "Arena Simulation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 16.00 - 16.20.02"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:rockwellautomation:arena_simulation:16.00.00:*:*:*:*:*:*:*"
          ],
          "vendor": "rockwellautomation",
          "product": "arena_simulation",
          "versions": [
            {
              "status": "affected",
              "version": "16.00",
              "lessThan": "16.20.03",
              "versionType": "custom"
            }
          ],
          "defaultStatus": "unknown"
        }
      ]
    }
  ],
  "published": "2024-03-26T16:15:10.440",
  "references": [
    {
      "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html",
      "tags": [
        "Broken Link"
      ],
      "source": "PSIRT@rockwellautomation.com"
    },
    {
      "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD-1665.html",
      "tags": [
        "Broken Link"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "PSIRT@rockwellautomation.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    },
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nAn arbitrary code execution vulnerability in Rockwell Automation Arena Simulation could let a malicious user insert unauthorized code into the software. This is done by writing beyond the designated memory area, which causes an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor.\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de ejecución de código arbitrario en Rockwell Automation Arena Simulation podría permitir que un usuario malintencionado inserte código no autorizado en el software. Esto se hace escribiendo más allá del área de memoria designada, lo que provoca una infracción de acceso. Una vez dentro, el actor de la amenaza puede ejecutar código dañino en el sistema. Esto afecta la confidencialidad, integridad y disponibilidad del producto. Para desencadenar esto, el usuario tendría que abrir, sin saberlo, un archivo malicioso compartido por el actor de la amenaza."
    }
  ],
  "lastModified": "2026-06-17T07:10:23.950",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:arena:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "7433512B-62BB-4412-BFBA-6EA4679B3778",
              "versionEndExcluding": "16.20.03",
              "versionStartIncluding": "16.00.00"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com"
}