CVE-2024-1969
Estado: AplazadaAlta (8.2)—
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H
- Puntuación base: 8.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.46%
- Percentil entre todas las CVEs puntuadas: 37
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-120
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-1969",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-1969",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-04-29T15:12:46.757035Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "VulnerabilityReporting@secomea.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 4.2,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "VulnerabilityReporting@secomea.com",
"affectedData": [
{
"vendor": "Secomea",
"modules": [
"webserver"
],
"product": "GateManager",
"versions": [
{
"status": "affected",
"version": "9.7",
"lessThan": "11.2.624095033",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:secomea:gatemanager:-:*:*:*:*:*:*:*"
],
"vendor": "secomea",
"product": "gatemanager",
"versions": [
{
"status": "affected",
"version": "9.7"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-29T14:15:08.430",
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/",
"source": "VulnerabilityReporting@secomea.com"
},
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "VulnerabilityReporting@secomea.com",
"description": [
{
"lang": "en",
"value": "CWE-120"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.\n\n"
},
{
"lang": "es",
"value": "La vulnerabilidad de copia de búfer sin verificar el tamaño de la entrada ('desbordamiento de búfer clásico') en Secomea GateManager (módulos de servidor web) permite el bloqueo de GateManager. Este problema afecta a GateManager: desde 9.7 antes de 11.2.624095033."
}
],
"lastModified": "2026-06-17T07:05:31.290",
"sourceIdentifier": "VulnerabilityReporting@secomea.com"
}