« Volver al listado

CVE-2024-13089

Estado: AplazadaAlta (7.5)—

An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands.

Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC.

While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified.

This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

🎯 Técnicas ATT&CK

Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.

Vulnerabilidad en validación de firma en actualización requiere autenticación (PR:H) y acceso de red (AV:N). Permite inyección de comandos OS (CWE-78) remota post-autenticación en servicios administrativos, típico de T1210 con impacto T1059 en ejecución de código arbitrario.

Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.

🛡️ Mitigaciones ATT&CK que cubren estas técnicas

Tecnologías afectadas (2)

⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2024-13089",
  "cveTags": [],
  "metrics": {
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-13089",
          "role": "CISA Coordinator",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "version": "2.0.3",
          "timestamp": "2025-06-10T14:28:44.178820Z"
        }
      }
    ],
    "cvssMetricV31": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "scope": "UNCHANGED",
          "version": "3.1",
          "baseScore": 7.2,
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "integrityImpact": "HIGH",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "availabilityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "confidentialityImpact": "HIGH"
        },
        "impactScore": 5.9,
        "exploitabilityScore": 1.2
      }
    ],
    "cvssMetricV40": [
      {
        "type": "Secondary",
        "source": "prodsec@nozominetworks.com",
        "cvssData": {
          "Safety": "NOT_DEFINED",
          "version": "4.0",
          "Recovery": "NOT_DEFINED",
          "baseScore": 7.5,
          "Automatable": "NOT_DEFINED",
          "attackVector": "NETWORK",
          "baseSeverity": "HIGH",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "exploitMaturity": "NOT_DEFINED",
          "providerUrgency": "NOT_DEFINED",
          "userInteraction": "NONE",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "privilegesRequired": "HIGH",
          "subIntegrityImpact": "NONE",
          "vulnIntegrityImpact": "HIGH",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "vulnAvailabilityImpact": "HIGH",
          "availabilityRequirement": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "subConfidentialityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED"
        }
      }
    ]
  },
  "affected": [
    {
      "source": "prodsec@nozominetworks.com",
      "affectedData": [
        {
          "vendor": "Nozomi Networks",
          "product": "Guardian",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "24.6.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        },
        {
          "vendor": "Nozomi Networks",
          "product": "CMC",
          "versions": [
            {
              "status": "affected",
              "version": "0",
              "lessThan": "24.6.0",
              "versionType": "semver"
            }
          ],
          "defaultStatus": "unaffected"
        }
      ]
    }
  ],
  "published": "2025-06-10T11:15:52.113",
  "references": [
    {
      "url": "https://security.nozominetworks.com/NN-2025:1-01",
      "source": "prodsec@nozominetworks.com"
    }
  ],
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "type": "Secondary",
      "source": "prodsec@nozominetworks.com",
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands.\n\n\n\nUsers with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC.\n\nWhile these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified.\n\nThis issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de inyección de comandos del sistema operativo en la funcionalidad de actualización podría permitir que un administrador autenticado ejecute comandos arbitrarios del sistema operativo no autorizados. Los usuarios con privilegios administrativos podrían cargar paquetes de actualización para actualizar las versiones de Nozomi Networks Guardian y CMC. Si bien estas actualizaciones están firmadas y sus firmas se validan antes de la instalación, se ha identificado una comprobación incorrecta de la validación de firmas. Este problema podría permitir que los usuarios ejecuten comandos de forma remota en el dispositivo, lo que afectaría la confidencialidad, la integridad y la disponibilidad."
    }
  ],
  "lastModified": "2026-06-17T07:01:09.187",
  "sourceIdentifier": "prodsec@nozominetworks.com"
}