CVE-2024-11013
Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.2
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.10%
- Percentil entre todas las CVEs puntuadas: 65
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
🎯 Técnicas ATT&CK
Cómo se explota esta vulnerabilidad y qué consigue el atacante, en el lenguaje de MITRE ATT&CK.
- Explotación
T1210Exploitation of Remote Serviceslateral movement85 % - Impacto principal
T1059Command and Scripting Interpreterexecution90 %
Inyección de comandos CLI via interfaz de gestión en dispositivo remoto (AV:N). Requiere privilegios altos (PR:H), característico de T1210. El impacto es ejecución arbitraria de comandos (CWE-77, descripción explícita).
Inferido por nuestro agente de análisis a partir de la descripción oficial, el vector CVSS y la CWE, y comprobado por un supervisor. Puede contener errores.
🛡️ Mitigaciones ATT&CK que cubren estas técnicas
Tecnologías afectadas (3)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-77
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-11013",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-11013",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-11-29T13:34:19.048337Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "psirt-info@cyber.jp.nec.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.2
}
]
},
"affected": [
{
"source": "psirt-info@cyber.jp.nec.com",
"affectedData": [
{
"vendor": "NEC Corporation",
"product": "UNIVERGE IX",
"versions": [
{
"status": "affected",
"version": "from Ver9.2 to Ver10.10.21"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "NEC Corporation",
"product": "UNIVERGE IX",
"versions": [
{
"status": "affected",
"version": "for Ver10.8 up to Ver10.8.27"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "NEC Corporation",
"product": "UNIVERGE IX",
"versions": [
{
"status": "affected",
"version": "for Ver10.9 up to Ver10.9.14"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "NEC Corporation",
"product": "UNIVERGE IX-R/IX-V",
"versions": [
{
"status": "affected",
"version": "Ver1.2.15 and earlier"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:nec:univerge_ix:*:*:*:*:*:*:*:*"
],
"vendor": "nec",
"product": "univerge_ix",
"versions": [
{
"status": "affected",
"version": "9.2",
"versionType": "custom",
"lessThanOrEqual": "10.10.21"
},
{
"status": "affected",
"version": "10.8",
"versionType": "custom",
"lessThanOrEqual": "10.8.27"
},
{
"status": "affected",
"version": "10.9",
"versionType": "custom",
"lessThanOrEqual": "10.9.14"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-11-29T08:15:03.923",
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv24-009_en.html",
"source": "psirt-info@cyber.jp.nec.com"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "psirt-info@cyber.jp.nec.com",
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Command Injection vulnerability in NEC Corporation UNIVERGE IX from Ver9.2 to Ver10.10.21, for Ver10.8 up to Ver10.8.27, for Ver10.9 up to Ver10.9.14 and UNIVERGE IX-R/IX-V Ver1.2.15 and earlier allows a attacker to inject an arbitrary CLI commands to be executed on the device via the management interface."
},
{
"lang": "es",
"value": "La vulnerabilidad de inyección de comandos en NEC Corporation UNIVERGE IX desde Ver9.2 hasta Ver10.10.21, desde Ver10.8 hasta Ver10.8.27, desde Ver10.9 hasta Ver10.9.14 y UNIVERGE IX-R/IX-V Ver1.2.15 y anteriores permite a un atacante inyectar comandos CLI arbitrarios para que se ejecuten en el dispositivo a través de la interfaz de administración."
}
],
"lastModified": "2026-06-17T06:56:53.087",
"sourceIdentifier": "psirt-info@cyber.jp.nec.com"
}