CVE-2024-0851
Estado: AplazadaCrítica (10)—
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.
This issue affects Smartpower: through V24.05.27.
CVSS
- Versión: 4.0
- Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- Puntuación base: 10
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.40%
- Percentil entre todas las CVEs puntuadas: 32
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
⚠ Inferidas por IA a partir de la descripción — NVD aún no ha analizado esta CVE; no son CPE verificados.
CWE
- CWE-89
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-0851",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-0851",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-31T16:47:36.786306Z"
}
}
],
"cvssMetricV40": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"cvssData": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 10,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "CRITICAL",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"subConfidentialityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED"
}
}
]
},
"affected": [
{
"source": "iletisim@usom.gov.tr",
"affectedData": [
{
"vendor": "Grup Arge Energy and Control Systems",
"product": "Smartpower",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "V24.05.27"
}
],
"defaultStatus": "unaffected"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:gruparge:smartpower:-:*:*:*:*:*:*:*"
],
"vendor": "gruparge",
"product": "smartpower",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "24.05.27"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-05-27T15:15:08.780",
"references": [
{
"url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-24-0556",
"source": "iletisim@usom.gov.tr"
},
{
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556",
"source": "iletisim@usom.gov.tr"
},
{
"url": "https://www.usom.gov.tr/bildirim/tr-24-0556",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Deferred",
"weaknesses": [
{
"type": "Secondary",
"source": "iletisim@usom.gov.tr",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Grup Arge Energy and Control Systems Smartpower allows SQL Injection.\n\nThis issue affects Smartpower: through V24.05.27."
},
{
"lang": "es",
"value": "Neutralización inadecuada de elementos especiales utilizados en una vulnerabilidad de Comando SQL ('Inyección SQL') en Grup Arge Energy and Control Systems Smartpower permite la Inyección SQL. Este problema afecta a Smartpower: hasta V24.05.27."
}
],
"lastModified": "2026-06-17T06:54:25.857",
"sourceIdentifier": "iletisim@usom.gov.tr"
}