CVE-2024-0317
Estado: ModificadaMedia (6.1)—
Cross-Site Scripting in FireEye EX, affecting version 9.0.3.936727. Exploitation of this vulnerability allows an attacker to send a specially crafted JavaScript payload via the 'type' and 's_f_name' parameters to an authenticated user to retrieve their session details.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- Puntuación base: 6.1
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.31%
- Percentil entre todas las CVEs puntuadas: 22
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (3)
CWE
- CWE-79
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2024-0317",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-0317",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2025-05-08T15:54:51.554395Z"
}
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 5.4,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.5,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "CHANGED",
"version": "3.1",
"baseScore": 6.1,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"integrityImpact": "LOW",
"userInteraction": "REQUIRED",
"attackComplexity": "LOW",
"availabilityImpact": "NONE",
"privilegesRequired": "NONE",
"confidentialityImpact": "LOW"
},
"impactScore": 2.7,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cve-coordination@incibe.es",
"affectedData": [
{
"vendor": "FireEye ",
"product": "FireEye EX",
"versions": [
{
"status": "affected",
"version": "9.0.3.936727"
}
],
"defaultStatus": "unaffected"
}
]
}
],
"published": "2024-01-15T17:15:08.850",
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-fireeye-products",
"tags": [
"Third Party Advisory"
],
"source": "cve-coordination@incibe.es"
},
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-fireeye-products",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cve-coordination@incibe.es",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Scripting in FireEye EX, affecting version 9.0.3.936727. Exploitation of this vulnerability allows an attacker to send a specially crafted JavaScript payload via the 'type' and 's_f_name' parameters to an authenticated user to retrieve their session details."
},
{
"lang": "es",
"value": "Cross site scripting en FireEye EX, que afectan a la versión 9.0.3.936727. La explotación de esta vulnerabilidad permite a un atacante enviar un payload de JavaScript especialmente manipulado a través de los parámetros 'type' y 's_f_name' a un usuario autenticado para recuperar los detalles de su sesión."
}
],
"lastModified": "2026-06-17T06:53:15.763",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fireeye:ex_5500_firmwarea:9.0.3.936727:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "B9FD56BD-467E-474E-9512-6C7578892E87"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fireeye:ex_5500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "C196CC1F-F9F0-4FA3-85B7-78ADD07D9BA7"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fireeye:ex_8500_firmware:9.0.3.936727:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "CADEC68D-AE9E-4BE5-AE8B-26DF54EA2626"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fireeye:ex_8500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "F0618D1C-184D-4F39-B86A-9A11BA6B7966"
}
],
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:fireeye:ex_3500_firmware:9.0.3.936727:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "EDF6F74D-AF80-4DCA-AD55-2B0C91097FC5"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:fireeye:ex_3500:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "62AC2BDE-60CE-40FD-AC51-F89BDB22FF3B"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cve-coordination@incibe.es"
}