CVE-2023-51571
Voltronic Power ViewPower Pro SocketService Missing Authentication Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the SocketService module, which listens on UDP port 41222 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21162.
CVSS
- Versión: 3.0
- Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Puntuación base: 7.5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.67%
- Percentil entre todas las CVEs puntuadas: 50
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-306
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-51571",
"cveTags": [],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-51571",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-04-02T15:09:17.525270Z"
}
}
],
"cvssMetricV30": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"integrityImpact": "NONE",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "NONE",
"confidentialityImpact": "NONE"
},
"impactScore": 3.6,
"exploitabilityScore": 3.9
}
]
},
"affected": [
{
"source": "zdi-disclosures@trendmicro.com",
"affectedData": [
{
"vendor": "Voltronic Power",
"product": "ViewPower Pro",
"versions": [
{
"status": "affected",
"version": "2.0-22165"
}
],
"defaultStatus": "unknown"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:a:voltronicpower:viewpower_pro:*:*:*:*:*:*:*:*"
],
"vendor": "voltronicpower",
"product": "viewpower_pro",
"versions": [
{
"status": "affected",
"version": "2.0-22165"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2024-04-01T22:15:09.673",
"references": [
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1877/",
"tags": [
"Third Party Advisory"
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1877/",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Analyzed",
"weaknesses": [
{
"type": "Secondary",
"source": "zdi-disclosures@trendmicro.com",
"description": [
{
"lang": "en",
"value": "CWE-306"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Voltronic Power ViewPower Pro SocketService Missing Authentication Denial-of-Service Vulnerability. This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the SocketService module, which listens on UDP port 41222 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21162."
},
{
"lang": "es",
"value": "Vulnerabilidad de denegación de servicio de autenticación faltante en Voltronic Power ViewPower Pro SocketService. Esta vulnerabilidad permite a atacantes remotos crear una condición de denegación de servicio en las instalaciones afectadas de Voltronic Power ViewPower Pro. No se requiere autenticación para aprovechar esta vulnerabilidad. La falla específica existe dentro del módulo SocketService, que escucha en el puerto UDP 41222 de forma predeterminada. El problema se debe a la falta de autenticación antes de permitir el acceso a la funcionalidad. Un atacante puede aprovechar esta vulnerabilidad para crear una condición de denegación de servicio en el sistema. Era ZDI-CAN-21162."
}
],
"lastModified": "2026-06-17T06:41:14.250",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:voltronicpower:viewpower:2.0-22165:*:*:*:pro:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3C4A08EC-F4D4-47F8-B531-547A286F3E17"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com"
}