CVE-2023-5151
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-8000 up to 20151231. Affected by this vulnerability is an unknown functionality of the file /autheditpwd.php. The manipulation of the argument hid_id leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240247. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 8.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 81%
- Percentil entre todas las CVEs puntuadas: 100
- Fecha de la puntuación: 4/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-89
Referencias
- https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_sql_%20autheditpwd.md
- https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354
- https://vuldb.com/?ctiid.240247
- https://vuldb.com/?id.240247
- https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_sql_%20autheditpwd.md
- https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354
- https://vuldb.com/?ctiid.240247
- https://vuldb.com/?id.240247
JSON original (NVD)
Mostrar
{
"id": "CVE-2023-5151",
"cveTags": [
{
"tags": [
"unsupported-when-assigned"
],
"sourceIdentifier": "cna@vuldb.com"
}
],
"metrics": {
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-5151",
"role": "CISA Coordinator",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2024-09-24T19:18:35.767733Z"
}
}
],
"cvssMetricV2": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"version": "2.0",
"baseScore": 6.5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"authentication": "SINGLE",
"integrityImpact": "PARTIAL",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 6.4,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 6.3,
"attackVector": "NETWORK",
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"integrityImpact": "LOW",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "LOW",
"privilegesRequired": "LOW",
"confidentialityImpact": "LOW"
},
"impactScore": 3.4,
"exploitabilityScore": 2.8
},
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 8.8,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 2.8
}
]
},
"affected": [
{
"source": "cna@vuldb.com",
"affectedData": [
{
"vendor": "D-Link",
"product": "DAR-8000",
"versions": [
{
"status": "affected",
"version": "20151231"
}
]
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"affectedData": [
{
"cpes": [
"cpe:2.3:o:dlink:dar-8000_firmware:*:*:*:*:*:*:*:*"
],
"vendor": "dlink",
"product": "dar-8000_firmware",
"versions": [
{
"status": "affected",
"version": "0",
"versionType": "custom",
"lessThanOrEqual": "2015-12-31"
}
],
"defaultStatus": "unknown"
}
]
}
],
"published": "2023-09-25T02:15:10.657",
"references": [
{
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_sql_%20autheditpwd.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354",
"tags": [
"Vendor Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?ctiid.240247",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://vuldb.com/?id.240247",
"tags": [
"Third Party Advisory"
],
"source": "cna@vuldb.com"
},
{
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-8000-10_sql_%20autheditpwd.md",
"tags": [
"Exploit",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?ctiid.240247",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://vuldb.com/?id.240247",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Secondary",
"source": "cna@vuldb.com",
"description": [
{
"lang": "en",
"value": "CWE-89"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-8000 up to 20151231. Affected by this vulnerability is an unknown functionality of the file /autheditpwd.php. The manipulation of the argument hid_id leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240247. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "es",
"value": "** NO SOPORTADO CUANDO ESTÁ ASIGNADO ** ** NO SOPORTADO CUANDO ESTÁ ASIGNADO ** Una vulnerabilidad ha sido encontrada en D-Link DAR-8000 hasta 20151231 y clasificada como crítica. Una función desconocida del archivo /autheditpwd.php es afectada por esta vulnerabilidad. La manipulación del argumento hid_id conduce a la inyección de SQL. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-240247. NOTA: Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el mantenedor. NOTA: Se contactó primeramente con el proveedor y se confirmó de inmediato que el producto ha llegado al final de su vida útil. Debería retirarse y reemplazarse."
}
],
"lastModified": "2026-06-17T06:47:39.790",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:dar-8000_firmware:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "69DE14E8-4D9F-4E0D-B322-720E07A49D40",
"versionEndIncluding": "2015-12-31"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:dar-8000:-:*:*:*:*:*:*:*",
"vulnerable": false,
"matchCriteriaId": "E74A904C-319A-4DC0-A0E2-2247272C68DE"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"sourceIdentifier": "cna@vuldb.com"
}